Literature DB >> 27567021

First prospective multicenter experience with the 7 French Glidesheath slender for complex transradial coronary interventions.

Adel Aminian1, Juan F Iglesias2, Carlos Van Mieghem3, Andrea Zuffi2, Angela Ferrara3, Roukos Manih1, Dariouch Dolatabadi1, Jacques Lalmand1, Shigeru Saito4.   

Abstract

PURPOSE: To assess the feasibility and safety of the 7 French (Fr) Glidesheath Slender for complex transradial (TR) percutaneous coronary interventions (PCI).
BACKGROUND: The TR approach is increasingly used worldwide for coronary and peripheral vascular interventions. However, the small size of the radial artery remains an important limitation for the use of large-bore guiding catheters (>6 Fr), restricting thereby the treatment of highly complex lesions through the TR approach. The 7 Fr Glidesheath slender (Terumo, Tokyo, Japan) is a new dedicated radial sheath with a thinner wall and hydrophilic coating. It combines an inner diameter compatible with any 7 Fr guiding catheter and an outer diameter smaller than current 7 Fr sheaths.
METHODS: Prospective multicenter registry of complex TR PCI cases using the 7 Fr Glidesheath Slender to determine the procedural success, rates of vascular complications, radial spasm, and radial artery occlusion (RAO).
RESULTS: A total of 60 patients were included. Procedural success was 97% with only one access-site crossover. The use of a 7 Fr guiding catheter was indicated for the treatment of highly complex coronary lesions including distal left main (LM) disease (n = 20), complex non-LM bifurcation lesions (n = 16), chronic total occlusion (n = 15), and severely calcified vessels requiring rotational atherectomy (n = 10). There were three vascular access-site complications (4.7%) including two moderate (type II) local hematoma and one uncomplicated guiding catheter-induced brachial artery dissection. None of the patients experienced major bleeding. The occurrence of radial spasm was reported in seven patients (11%). Doppler ultrasound imaging of the radial artery at 1 month was available in 62 of 64 radial access with three cases of RAO (4.8%).
CONCLUSIONS: Use of the 7 Fr Glidesheath slender for complex coronary interventions is feasible and associated with a high rate of procedural success and a low rate of vascular complications. These favorable results need be confirmed in larger multicenter studies.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  complex PCI; radial occlusion; radial sheath; slender; transradial access; transradial approach

Mesh:

Year:  2016        PMID: 27567021     DOI: 10.1002/ccd.26773

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  13 in total

Review 1.  Radial Access for Lower Extremity Peripheral Arterial Interventions: Do We Have the Tools?

Authors:  Raghuram Posham; Lindsay B Young; Robert A Lookstein; Constantino Pena; Rahul S Patel; Aaron M Fischman
Journal:  Semin Intervent Radiol       Date:  2019-02-05       Impact factor: 1.513

2.  Comparison of long-term radial artery occlusion following trans-radial coronary intervention using 6-french versus 7-french sheaths.

Authors:  Yanming Fan; Qingmin Wei; Junna Cai; Yanbo Wang; Xianghua Fu
Journal:  Cardiol J       Date:  2019-09-03       Impact factor: 2.737

3.  The comparison of efficacy and safety between transradial and transfemoral approach for chronic total occlusions intervention: a meta-analysis.

Authors:  Chiung-Jen Wu; Ping-Yen Liu; Wei-Chieh Lee; Po-Jui Wu; Chih-Yuan Fang; Hsiu-Yu Fang
Journal:  Sci Rep       Date:  2022-05-09       Impact factor: 4.996

4.  Perioperative neurologic outcomes of right versus left upper extremity access for fenestrated-branched endovascular aortic aneurysm repair.

Authors:  Carla K Scott; Anna L Driessen; Marilisa Soto Gonzalez; Fatemeh Malekpour; Gerardo G Guardiola; Mirza S Baig; Melissa L Kirkwood; Carlos H Timaran
Journal:  J Vasc Surg       Date:  2021-09-28       Impact factor: 4.860

5.  Technical Considerations in Transradial Unprotected Left Main Stem Rotational Atherectomy-Assisted and IVUS-Guided Percutaneous Coronary Intervention Using the 7.5F Eaucath Sheathless Guiding Catheter System.

Authors:  George Kassimis; Nicholas Weight; Nestoras Kontogiannis; Tushar Raina
Journal:  Cardiol Res       Date:  2018-08-10

6.  Feasibility and Safety of the Left Distal Radial Approach in Percutaneous Coronary Intervention for Bifurcation Lesions.

Authors:  Oh-Hyun Lee; Ji Woong Roh; Eui Im; Deok-Kyu Cho; Myung Ho Jeong; Donghoon Choi; Yongcheol Kim
Journal:  J Clin Med       Date:  2021-05-19       Impact factor: 4.241

7.  Complex Large-Bore Radial percutaneous coronary intervention: rationale of the COLOR trial study protocol.

Authors:  Thomas A Meijers; Adel Aminian; Koen Teeuwen; Marleen van Wely; Thomas Schmitz; Maurits T Dirksen; Rene J van der Schaaf; Juan F Iglesias; Pierfrancesco Agostoni; Joseph Dens; Paul Knaapen; Sudhir Rathore; Jan Paul Ottervanger; Jan-Henk E Dambrink; Vincent Roolvink; A T Marcel Gosselink; Renicus S Hermanides; Niels van Royen; Maarten A H van Leeuwen
Journal:  BMJ Open       Date:  2020-07-20       Impact factor: 2.692

8.  Comparison between radial versus femoral percutaneous coronary intervention access in Indonesian hospitals, 2017-2018: A prospective observational study of a national registry.

Authors:  Amir Aziz Alkatiri; Doni Firman; Nur Haryono; Emir Yonas; Raymond Pranata; Ismir Fahri; I Made Junior Rina Artha; Vireza Pratama; Wishnu Aditya Widodo; Nahar Taufiq; Abdul Hakim Alkatiri; Sunanto Ng; Heru Sulastomo; Sunarya Soerianata
Journal:  Int J Cardiol Heart Vasc       Date:  2020-03-02

9.  Comparison of transradial coronary intervention for left main bifurcation disease using the new Braidin® slender 7 Fr sheath and a standard 6 Fr sheath.

Authors:  Yingkai Xu; Yingkai Li; Jiancai Yu; Deguang Wang; Qi Zhao; Yujing Cheng; Yujie Zhou
Journal:  J Int Med Res       Date:  2020-09       Impact factor: 1.671

10.  Slender Sheath/Guiding Catheter Combination vs. Sheathless Guiding Catheter for Acute Coronary Syndrome: A Propensity-Matched Analysis of the Two Devices.

Authors:  Tsuyoshi Isawa; Kazunori Horie; Taku Honda; Masataka Taguri; Norio Tada
Journal:  J Interv Cardiol       Date:  2020-08-14       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.