Literature DB >> 27566858

Occurrence of UV filters, fragrances and organophosphate flame retardants in municipal WWTP effluents and their removal during membrane post-treatment.

P Krzeminski1, C Schwermer2, A Wennberg2, K Langford2, C Vogelsang2.   

Abstract

Membrane filtration using ultrafiltration (UF), nanofiltration (NF) or reverse osmosis (RO) membranes was evaluated as an efficient effluent polishing step at municipal wastewater treatment plants (WWTPs) for the removal of selected contaminants of emerging concern and for improvement of water quality according to water reuse requirements. In samples collected at two largest WWTPs in Norway, 12 out of 14 selected personal care products and organophosphate flame retardants (OPFRs) were found above analytical detection limit. The highest concentrations were observed for BP3, OC (UV filters), HHCB, AHTN (fragrances), TCPP and TBP (OPFRs), exceeding the predicted no-effect concentration for BP3 in one sample and AHTN in five samples. Independently of the membrane type used, membrane filtration effectively (>60%) removed BP3, UV-329, OC, HHCB, AHTN and DBPP. However, UF was insufficient (<20%) for removal of DEET, TCPP and TCEP. UF was sufficient to remove 30-50% of COD, 80-95% of TP, up to 30% of TN and NH4, and a min of 2log reduction of E. coli. Water quality improved further with application of NF and RO. The results indicate that membrane filtration can be effective post-treatment to improve overall water quality and a measure to reduce potential risk in the receiving aquatic environment. Copyright Â
© 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  (max 5): municipal WWTP; Effluent polishing; Membrane post-treatment; Removal of CECs

Year:  2016        PMID: 27566858     DOI: 10.1016/j.jhazmat.2016.08.001

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  5 in total

1.  A nationwide survey of 31 organophosphate esters in sewage sludge from the United States.

Authors:  Yu Wang; Pranav Kannan; Rolf U Halden; Kurunthachalam Kannan
Journal:  Sci Total Environ       Date:  2018-11-16       Impact factor: 7.963

2.  Occurrence, seasonal variation and environmental impact of phosphorus flame retardants in a large scale wastewater treatment plant.

Authors:  Zhineng Liu; Mingjun Deng; Qihang Wu; Dave T F Kuo; Lixi Zeng; Zhu Wang; Ying Zhang; Xinyu Liu; Shengyu Liu; Junyan Liang; Xiaodong Hu; Bixian Mai
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-12       Impact factor: 4.223

3.  Degradation of UV-filter Benzophenon-3 in aqueous solution using TiO2 coated on quartz tubes.

Authors:  Nazanin Moradi; Mohammad Mehdi Amin; Ali Fatehizadeh; Zahra Ghasemi
Journal:  J Environ Health Sci Eng       Date:  2018-08-15

4.  Comprehensive Genomic Survey of Antimicrobial-Resistance Bacteria in the Sewage Tank Replacement with Hospital Relocation.

Authors:  Miwa Katagiri; Makoto Kuroda; Tsuyoshi Sekizuka; Norihide Nakada; Yukitaka Ito; Masanobu Otsuka; Manabu Watanabe; Shinya Kusachi
Journal:  Infect Drug Resist       Date:  2021-12-20       Impact factor: 4.003

5.  Occurrence, Distribution, and Risk of Organophosphate Flame Retardants in Sediments from Jiulong River Estuary and Adjacent Western Taiwan Strait, China.

Authors:  Ling Cai; Yuwei Shi; Chenyuan Pan; Feng Zhu; Siqi Wang; Juanjuan Dai; Ming Yang; Jing Ma
Journal:  Int J Environ Res Public Health       Date:  2022-02-20       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.