Literature DB >> 27564310

Randomised comparison of a bioresorbable everolimus-eluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions: the 2-year clinical outcomes of the ABSORB II trial.

Bernard Chevalier1, Yoshinobu Onuma, Ad J van Boven, Jan J Piek, Manel Sabaté, Steffen Helqvist, Andreas Baumbach, Pieter C Smits, Ravindra Kumar, Luc Wasungu, Patrick W Serruys.   

Abstract

AIMS: The one-year randomised data of the ABSORB II trial showed that the everolimus-eluting bioresorbable scaffold and the everolimus-eluting metallic stent were comparable for the composite secondary clinical outcomes of patient-oriented composite endpoint (PoCE) and device-oriented composite endpoint (DoCE)/target lesion failure (TLF), MACE and TVF. This report describes the two-year clinical outcomes of the ABSORB II trial. METHODS AND
RESULTS: Patients were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb; Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (XIENCE; Abbott Vascular). The trial enrolled 501 patients. Clinical follow-up at two years was available in 320 patients in the Absorb BVS arm and 160 patients in the XIENCE arm. At two years, the PoCE for the Absorb and XIENCE arms was 11.6% and 12.8% (p=0.70) and the DoCE/TLF was 7.0% and 3.0% (p=0.07), respectively. The hierarchical ID-MACE rate was 7.6% vs. 4.3% (p=0.16) and the rate of TVF was 8.5% vs. 6.7% (p=0.48). The definite/probable thrombosis rate was 1.5% in the Absorb arm vs. 0% in the XIENCE arm (p=0.17). Thirty-six percent and 34% of patients remained on DAPT at two years, respectively. Ninety-two percent of patients in both arms remained on aspirin.
CONCLUSIONS: Two-year clinical results demonstrate sustained low rates of PoCE, MACE, DoCE and TVF with the Absorb BVS as compared to the XIENCE stent.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27564310     DOI: 10.4244/EIJY16M08_01

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  7 in total

1.  Bioresorbable vascular scaffolds for complex coronary anatomies: "Icarus' flight" for interventional cardiologists?

Authors:  Salvatore Cassese; Adnan Kastrati; Massimiliano Fusaro
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

2.  Bioresorbable scaffolds versus metallic stents in routine PCI: the plot thickens.

Authors:  Athanasios Katsikis; Patrick W Serruys
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

Review 3.  Long-term outcome of bioresorbable vascular scaffolds for the treatment of coronary artery disease: a meta-analysis of RCTs.

Authors:  Alberto Polimeni; Remzi Anadol; Thomas Münzel; Ciro Indolfi; Salvatore De Rosa; Tommaso Gori
Journal:  BMC Cardiovasc Disord       Date:  2017-06-07       Impact factor: 2.298

4.  Bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: a meta-analysis.

Authors:  Alberto Polimeni; Remzi Anadol; Thomas Münzel; Martin Geyer; Salvatore De Rosa; Ciro Indolfi; Tommaso Gori
Journal:  BMC Cardiovasc Disord       Date:  2019-03-15       Impact factor: 2.298

5.  Mechanical performance and healing patterns of the novel sirolimus-eluting bioresorbable Fantom scaffold: 6-month and 9-month follow-up by optical coherence tomography in the FANTOM II study.

Authors:  Jo Krogsgaard Simonsen; Emil Nielsen Holck; Didier Carrié; Norbert Frey; Matthias Lutz; Joachim Weber-Albers; Dariusz Dudek; Bernard Chevalier; Joost Daemen; Jouke Dijkstra; Camilla Fox Maule; Omeed Neghabat; Jens Flensted Lassen; Jeffrey Anderson; Evald Høj Christiansen; Alexandre Abizaid; Niels Ramsing Holm
Journal:  Open Heart       Date:  2019-02-28

6.  The impact of the use of bioresorbable vascular scaffolds and drug-coated balloons in coronary bifurcation lesions.

Authors:  Mostafa Elwany; Amr Zaki; Azeem Latib; Luca Testa; Alfonso Ielasi; Davide Piraino; Salvatore Geraci; Tarek El Zawawy; Bernardo Cortese
Journal:  Egypt Heart J       Date:  2019-12-16

7.  Two-stage degradation and novel functional endothelium characteristics of a 3-D printed bioresorbable scaffold.

Authors:  Tieying Yin; Ruolin Du; Yang Wang; Junyang Huang; Shuang Ge; Yuhua Huang; Youhua Tan; Qing Liu; Zhong Chen; Hanqing Feng; Jie Du; Yazhou Wang; Guixue Wang
Journal:  Bioact Mater       Date:  2021-08-24
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.