| Literature DB >> 27562834 |
Utku Dolen1, Justin B Cohen1, Bo Overschmidt1, Marissa M Tenenbaum1, Terence M Myckatyn2.
Abstract
BACKGROUND: Tissue liquefaction technology (TLT) delivers warmed saline from the liposuction cannula tip at low pressure pulses to disaggregate adipocytes. This technology differs significantly from that used in other liposuction devices including water jet-assisted liposuction. Here we introduce our early experience with this technology in the setting of fat transfer for revision breast reconstruction.Entities:
Keywords: Breast reconstruction; Fat graft; Fat transfer; Liposuction; Tissue liquefaction technology
Mesh:
Year: 2016 PMID: 27562834 PMCID: PMC5133286 DOI: 10.1007/s00266-016-0690-1
Source DB: PubMed Journal: Aesthetic Plast Surg ISSN: 0364-216X Impact factor: 2.326
Demographic and clinical characteristics organized by development of fat necrosis
| Fat necrosis | ||||
|---|---|---|---|---|
| Total | No | Yes |
| |
|
|
|
| ||
| Number of patients | 136 | 106 | 30 | |
| Age (years) | 48 | 48 | 47 | 0.894 |
| BMI (kg/m2) | 26.8 | 25.8 | 27.5 | 0.244 |
| DM | 7 (5.9) | 5 (5.7) | 2 (6.7) | 0.468 |
| CHF | 25 (18.4) | 21 (19.8) | 4 (13.3) | 0.311 |
| Smoking | 0.775 | |||
| Never | 103 (75.7) | 81 (76.4) | 22 (73.3) | |
| Prior | 31 (22.8) | 23 (21.7) | 8 (26.7) | |
| Current | 2 (1.5) | 2 (1.9) | 0 | |
| Radiotherapy to breast | 0.542 | |||
| Yes | 58 (24.5) | 49 (24.4) | 9 (25) | |
| No | 179 (75.5) | 152 (75.6) | 27 (75) | |
| Reconstruction type per breast ( | 0.84 | |||
| Implant | 179 (75.5) | 151 (75.1) | 28 (77.8) | |
| Autologous | 58 (24.5) | 50 (24.9) | 8 (22.2) | |
| Liposuction region | 0.702 | |||
| Abdomen | 66 (48.5) | 53 (50) | 13 (43.3) | |
| Flank | 39 (28.7) | 30 (28.3) | 9 (30) | |
| Others (Thigh, bra strap) | 6 (4.4) | 5 (4.6) | 1 (3.3) | |
| 2 or more regions | 25 (18.4) | 18 (27.1) | 7 (23.4) | |
| Tumescence volume (ml) | 1500 | 1600 | 1325 | 0.62 |
| Grafted fat volume (ml) per breast ( | 90 | 90 | 85 | 0.2 |
| Operation duration (min) | 79 | 79 | 85 | 0.12 |
| Follow-up (days) | 142.5 | 134.5 | 198 | 0.005 |
Fat transfer complications at the recipient site when using tissue liquefaction technology (TLT) for graft harvest
| Complications | |
|---|---|
| Fat necrosis | |
| Clinically exam only | 12 (8.8 %) |
| Clinical exam + imaging (MRI/ultrasound) | 30 (22.1 %) |
| Hematoma | 2 (1.5) |
| Cellulitis | 2 (1.5) |
| Wound dehiscence | 2 (1.5) |
| Pain | 2 (1.5) |
| DVT | 1 (0.6) |
| No | 97 (71.3) |
No complications were noted at the donor site
Fig. 1Regression analysis of fat necrosis adjusted to diabetes mellitus, hypertension, age, smoking status, and BMI stratification by patient (n = 136)
Fig. 2Regression analysis of fat necrosis adjusted to breast reconstruction method, fat donor region, volume of fat graft, and radiotherapy by breast (n = 237)
Fig. 3Regression analysis of severe ecchymosis of donor area adjusted to age, BMI, tumescence volume, fat graft volume, and duration of surgery in patients (n = 136)