Literature DB >> 27562773

Can treatment with statins have a negative influence on the tolerance of mandibular advancement devices?

Mónica González1, Emilio Macias-Escalada2, Juan Cobo2, Maria Pilar Fernández Mondragón3, Gerardo Gómez-Moreno4, Marian Martínez-Martínez1, Felix de Carlos5.   

Abstract

BACKGROUND: Statins are considered the most effective drugs used in the treatment of dyslipidemias. Some of their adverse effects are related to muscle problems. Myalgias produced by statins appear more often during exercise. Mandibular advancement devices (MAD) force the propulsory and elevatory musculature of the mandible to exercise by making the jaw move forward. The aim of this study is to evaluate the incidence of muscular side effects (referred, spontaneous, or under palpation pain, myofascial pain, mandibular rigidity and fatigue, tension and sensitivity of the masticatory muscles) in a group of patients with a diagnosis of obstructive sleep apnea being treated with MAD.
METHODS: This was a prospective study, involving consecutively 104 patients with a diagnosis of OSAS, and who had begun treatment with a custom made oral device. Muscular side effects were collected by anamnesis (verbal request and questionnaires), psychological status and clinical assessment (manual muscle palpation in the masticatory and cervical muscle groups), before and during MAD treatment.
RESULTS: Of the total sample, 22.1 % presented muscular side effects with the oral device. However, in patients taking statins, this percentage was 57.1 %, as opposed to 16.7 % of the non-statins patients (p < 0.001). The risk of suffering muscular alterations during oral device treatment is higher in statin patients (odds ratio 6.67, p = 0.002).
CONCLUSION: Treatment with statins can give rise to the appearance of undesirable side effects among patients being treated with oral devices.

Entities:  

Keywords:  Dyslipidemias; Mandibular advancement devices; Myotoxicity; Sleep apnea; Statins

Mesh:

Substances:

Year:  2016        PMID: 27562773     DOI: 10.1007/s11325-016-1399-8

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  7 in total

1.  Long-term oral appliance therapy in obstructive sleep apnea syndrome: a controlled study on temporomandibular side effects.

Authors:  Michiel H J Doff; Steffanie K B Veldhuis; Aarnoud Hoekema; James J R Huddleston Slater; P J Wijkstra; Lambert G M de Bont; Boudewijn Stegenga
Journal:  Clin Oral Investig       Date:  2011-05-03       Impact factor: 3.573

Review 2.  Myopathy in older people receiving statin therapy: a systematic review and meta-analysis.

Authors:  Roli B Iwere; Jonathan Hewitt
Journal:  Br J Clin Pharmacol       Date:  2015-07-22       Impact factor: 4.335

Review 3.  Muscle-related side-effects of statins: from mechanisms to evidence-based solutions.

Authors:  Beth A Taylor; Paul D Thompson
Journal:  Curr Opin Lipidol       Date:  2015-06       Impact factor: 4.776

4.  Comparative effects of two oral appliances on upper airway structure in obstructive sleep apnea.

Authors:  Kate Sutherland; Sheryn A Deane; Andrew S L Chan; Richard J Schwab; Andrew T Ng; M Ali Darendeliler; Peter A Cistulli
Journal:  Sleep       Date:  2011-04-01       Impact factor: 5.849

Review 5.  Oral appliance treatment for obstructive sleep apnea: an update.

Authors:  Kate Sutherland; Olivier M Vanderveken; Hiroko Tsuda; Marie Marklund; Frederic Gagnadoux; Clete A Kushida; Peter A Cistulli
Journal:  J Clin Sleep Med       Date:  2014-02-15       Impact factor: 4.062

Review 6.  Statin-associated muscle symptoms: impact on statin therapy-European Atherosclerosis Society Consensus Panel Statement on Assessment, Aetiology and Management.

Authors:  Erik S Stroes; Paul D Thompson; Alberto Corsini; Georgirene D Vladutiu; Frederick J Raal; Kausik K Ray; Michael Roden; Evan Stein; Lale Tokgözoğlu; Børge G Nordestgaard; Eric Bruckert; Guy De Backer; Ronald M Krauss; Ulrich Laufs; Raul D Santos; Robert A Hegele; G Kees Hovingh; Lawrence A Leiter; Francois Mach; Winfried März; Connie B Newman; Olov Wiklund; Terry A Jacobson; Alberico L Catapano; M John Chapman; Henry N Ginsberg
Journal:  Eur Heart J       Date:  2015-02-18       Impact factor: 29.983

7.  Statin intolerance - an attempt at a unified definition. Position paper from an International Lipid Expert Panel.

Authors:  Maciej Banach; Manfredi Rizzo; Peter P Toth; Michel Farnier; Michael H Davidson; Khalid Al-Rasadi; Wilbert S Aronow; Vasilis Athyros; Dragan M Djuric; Marat V Ezhov; Robert S Greenfield; G Kees Hovingh; Karam Kostner; Corina Serban; Daniel Lighezan; Zlatko Fras; Patrick M Moriarty; Paul Muntner; Assen Goudev; Richard Ceska; Stephen J Nicholls; Marlena Broncel; Dragana Nikolic; Daniel Pella; Raman Puri; Jacek Rysz; Nathan D Wong; Laszlo Bajnok; Steven R Jones; Kausik K Ray; Dimitri P Mikhailidis
Journal:  Arch Med Sci       Date:  2015-03-14       Impact factor: 3.318

  7 in total
  2 in total

Review 1.  Update on Oral Appliance Therapy for OSA.

Authors:  M Marklund
Journal:  Curr Sleep Med Rep       Date:  2017-07-10

2.  Night sleep duration and risk of each lipid profile abnormality in a Chinese population: a prospective cohort study.

Authors:  Qiaofeng Song; Xiaoxue Liu; Wenhua Zhou; Shouling Wu; Xizhu Wang
Journal:  Lipids Health Dis       Date:  2020-08-15       Impact factor: 3.876

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.