Literature DB >> 27555229

Fiducial marker guided stereotactic liver radiotherapy: Is a time delay between marker implantation and planning CT needed?

Esben S Worm1, Jenny Bertholet2, Morten Høyer3, Walther Fledelius4, Anders T Hansen5, Lars P Larsen6, Jens E Nielsen6, Per R Poulsen3.   

Abstract

To minimize the risk of marker migration in fiducial marker guided liver SBRT it is common to add a delay of a week between marker implantation and planning CT. This study found that such a delay is unnecessary and could be avoided to minimize the treatment preparation time.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Keywords:  Fiducial marker migration; Image-guidance; Liver SBRT

Mesh:

Year:  2016        PMID: 27555229     DOI: 10.1016/j.radonc.2016.07.023

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumours.

Authors:  Masao Nakayama; Kazuyuki Uehara; Hideki Nishimura; Shuhei Tamura; Yoshiki Munetomo; Shinji Tsudou; Hiroshi Mayahara; Naritoshi Mukumoto; Moshi Geso; Ryohei Sasaki
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-21

2.  MR-guided adaptive versus ITV-based stereotactic body radiotherapy for hepatic metastases (MAESTRO): a randomized controlled phase II trial.

Authors:  P Hoegen; K S Zhang; E Tonndorf-Martini; F Weykamp; S Regnery; P Naumann; K Lang; J Ristau; S A Körber; C Dreher; C Buchele; C Rippke; C K Renkamp; K M Paul; L König; C Büsch; J Krisam; O Sedlaczek; H-P Schlemmer; M Niyazi; S Corradini; J Debus; S Klüter; J Hörner-Rieber
Journal:  Radiat Oncol       Date:  2022-03-27       Impact factor: 3.481

3.  Accuracy and consistency of intensity-based deformable image registration in 4DCT for tumor motion estimation in liver radiotherapy planning.

Authors:  José D Tascón-Vidarte; Line Bjerregaard Stick; Mirjana Josipovic; Signe Risum; Julien Jomier; Kenny Erleben; Ivan Richter Vogelius; Sune Darkner
Journal:  PLoS One       Date:  2022-07-08       Impact factor: 3.752

4.  Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold.

Authors:  Line Bjerregaard Stick; Ivan Richter Vogelius; Signe Risum; Mirjana Josipovic
Journal:  Br J Radiol       Date:  2020-09-11       Impact factor: 3.039

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.