OBJECTIVE: To compare the efficacy of lightwand-guided classic laryngeal mask airway (cLMA) real-time insertion technique with the standard recommended index finger-guided insertion technique.
DESIGN: Prospective, randomized controlled study.
SETTING: University-affiliated hospital. PATIENTS: Three hundred patients undergoing minor gynecological or orthopedic surgeries under general anesthesia using the cLMA as an airway management tool.
INTERVENTIONS: Patients were randomly divided into either lightwand-guided group or standard group. MEASUREMENTS: Fiberoptic bronchoscopy was used to determine the cLMA position after a cLMA was inserted. The first attempt and total success rates of the cLMA insertion, insertion time, distances from the end of cLMA pilot tube to the upper central incisors, views of fiberoptic bronchoscopy, blood staining, tidal volume, airway pressure, end-tidal CO2, SpO2, noninvasive hemodynamic parameters, and others were compared. MAIN
RESULTS: The cLMA was all successfully inserted within 3 attempts except for 2 patients in the standard group. The success rates of lightwand-guided insertion technique at first attempt were significantly higher than standard insertion technique; the ideal view rates assessed by fiberoptic bronchoscopy in lightwand-guided group patients were also significantly higher than in standard group patients, but the insertion time of first successful attempt was similar; the blood staining rates on the cLMA in lightwand-guided group patients were significantly less than in standard group patients. The depths of cLMA insertion in standard group patients were significantly deeper than those in lightwand-guided group patients. There was no significant difference in end-tidal CO2, SpO2, airway pressure, and hemodynamic variables.
CONCLUSION: Lightwand-guided cLMA insertion technique can provide a more objective indicator for correct cLMA positioning, higher first attempt success rates, better glottic views, and less damage to oropharyngeal or esophagus tissues than standard index finger-guided cLMA insertion technique.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Airway management; Insertion technique; Laryngeal mask airway; Lightwand

Mesh:

Year:  2016        PMID: 27555183     DOI: 10.1016/j.jclinane.2016.04.032

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  4 in total

1.  Supraglottic Airway Devices: the Search for the Best Insertion Technique or the Time to Change Our Point of View?

Authors:  Massimiliano Sorbello; Flavia Petrini
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-04-01

2.  Lightwand-Guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison with Standard Digital Manipulation Insertion.

Authors:  Dae Hee Kim; Yun Jeong Chae; Sang Kee Min; Eun Ji Ha; Ji Young Yoo
Journal:  Med Sci Monit       Date:  2021-01-11

3.  Comparison of the efficacy of Macintosh laryngoscope-guided insertion of I-gel™ with the conventional blind insertion technique - A randomised study.

Authors:  Ankit Vyas; Pooja Bihani; Rishabh Jaju; Naveen Paliwal; Mathura L Tak; Usha Choudhary
Journal:  Indian J Anaesth       Date:  2022-06-21

4.  Application of lower limb nerve block combined with slow induction of light general anesthesia and tracheal induction in elderly hip surgery.

Authors:  Zheng-Yuan Shi; Chun-Nan Jiang; Gang Shao
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.