Literature DB >> 27554616

Does perfusion CT play a role in the evaluation of percutaneous microwave-ablated lung tumours?

N Parvizi1, D Chung1, M W Little1, F V Gleeson1, E M Anderson2.   

Abstract

AIM: To assess the clinical utility of perfusion computed tomography (pCT) parameters in microwave ablation (MWA) of lung tumours.
MATERIALS AND METHODS: Patients were included who had primary or metastatic lung tumours and underwent pCT studies immediately pre- and post-MWA. Perfusion maps of the tumours were constructed using CT perfusion software (GE, Milwaukee, WI, USA). Regions of interest were drawn on sequential axial sections to extract the pCT parameters, blood volume (BV), average blood flow (BF), and mean transit time (MTT) from the entire tumour volume. Direct visualisation of perfusion maps were performed by two experienced readers blinded to outcome. Data were analysed using the Mann-Whitney test.
RESULTS: Thirty-one patients with 34 lung tumours had follow-up data at 12 months. The median tumour diameter was 19 mm (10-52 mm). Seven patients developed local tumour progression (LTP) at 12 months. There was no statistical difference between patients with LTP and complete treatment based on quantitative pCT parameters. Using radiologist visualisation of perfusion maps, there was moderate agreement between the two readers (kappa coefficient 0.53) with a combined 96% sensitivity, 62% specificity, 91% positive predictive value, and 80% negative predictive value.
CONCLUSION: Quantitative pCT parameters do not help differentiate between LTP and complete treatment, but subjective analysis of perfusion maps may be a useful assessment tool for identifying treatment adequacy potentially enabling identification of areas requiring further treatment at the time of the procedure.
Copyright © 2016 The Royal College of Radiologists. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27554616     DOI: 10.1016/j.crad.2016.07.005

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

Review 1.  CT-guided percutaneous laser ablation of metastatic lung cancer: three cases report and literature review.

Authors:  Qiyu Zhao; Guo Tian; Fen Chen; Liyun Zhong; Tian'an Jiang
Journal:  Oncotarget       Date:  2017-01-10

2.  CT perfusion imaging can detect residual lung tumor early after radiofrequency ablation: a preliminary animal study on both tumoral and peri-tumoral region assessment.

Authors:  Zenghui Cheng; Yixue Wang; Min Yuan; Jianxiao Liang; Yanling Feng; Yuxin Shi; Zhiyong Zhang; Fei Shan
Journal:  J Thorac Dis       Date:  2022-01       Impact factor: 2.895

3.  Assessment of safety margin after microwave ablation of stage I NSCLC with three-dimensional reconstruction technique using CT imaging.

Authors:  Peng Yan; An-Na Tong; Xiu-Li Nie; Min-Ge Ma
Journal:  BMC Med Imaging       Date:  2021-06-07       Impact factor: 1.930

  3 in total