OBJECTIVES: The aims of this study were to introduce the measure noise texture deviation as quantitative parameter for evaluating iterative reconstruction (IR)-specific artifacts in computed tomography (CT) images and to test whether IR-specific artifacts, quantified through this measure, are reduced in advanced modeled IR (ADMIRE) as compared with sinogram-affirmed IR (SAFIRE) images of the liver ex vivo and in patients with hypodense liver lesions. MATERIALS AND METHODS: In the ex vivo study part, an abdominal phantom was used. In the institutional review board-approved in vivo study part, 40 consecutive patients (mean age, 63 years) with hypodense liver lesions undergoing abdominal CT in the portal-venous phase were included. Images were reconstructed with filtered back projection, with the second-generation IR algorithm SAFIRE and with the third-generation IR algorithm ADMIRE. Noise power spectra and noise texture deviation were calculated in the phantom; image noise was measured in the phantom and in patients. Two blinded readers evaluated all image data regarding IR-specific artifacts (plastic-like, blotchy appearance); patient data were evaluated regarding conspicuity and confidence for detecting hypodense liver lesions. RESULTS: Image noise was significantly reduced at increasing IR levels (P < 0.001) with both algorithms, with no significant differences between corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise power spectra were similar at corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise texture deviation in ADMIRE was reduced compared with corresponding strength levels of SAFIRE (all, P < 0.001) and strongly correlated with subjective IR-specific artifacts (r = 0.88, P < 0.001). Iterative reconstruction-specific artifacts were significantly reduced in ADMIRE compared with that in SAFIRE images at strength levels 3 or greater, both ex vivo and in vivo (all, P < 0.001). There were no significant differences in the readers' ratings of lesion conspicuity and lesion confidence in detecting hypodense liver lesions between SAFIRE and ADMIRE (P > 0.05). Only lesion conspicuity was superior with SAFIRE and ADMIRE compared with filtered back projection (all, P < 0.001). CONCLUSIONS: Noise texture deviation is a quantitative measure reflecting IR-specific artifacts and is reduced in CT images with ADMIRE compared with SAFIRE.
OBJECTIVES: The aims of this study were to introduce the measure noise texture deviation as quantitative parameter for evaluating iterative reconstruction (IR)-specific artifacts in computed tomography (CT) images and to test whether IR-specific artifacts, quantified through this measure, are reduced in advanced modeled IR (ADMIRE) as compared with sinogram-affirmed IR (SAFIRE) images of the liver ex vivo and in patients with hypodense liver lesions. MATERIALS AND METHODS: In the ex vivo study part, an abdominal phantom was used. In the institutional review board-approved in vivo study part, 40 consecutive patients (mean age, 63 years) with hypodense liver lesions undergoing abdominal CT in the portal-venous phase were included. Images were reconstructed with filtered back projection, with the second-generation IR algorithm SAFIRE and with the third-generation IR algorithm ADMIRE. Noise power spectra and noise texture deviation were calculated in the phantom; image noise was measured in the phantom and in patients. Two blinded readers evaluated all image data regarding IR-specific artifacts (plastic-like, blotchy appearance); patient data were evaluated regarding conspicuity and confidence for detecting hypodense liver lesions. RESULTS: Image noise was significantly reduced at increasing IR levels (P < 0.001) with both algorithms, with no significant differences between corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise power spectra were similar at corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise texture deviation in ADMIRE was reduced compared with corresponding strength levels of SAFIRE (all, P < 0.001) and strongly correlated with subjective IR-specific artifacts (r = 0.88, P < 0.001). Iterative reconstruction-specific artifacts were significantly reduced in ADMIRE compared with that in SAFIRE images at strength levels 3 or greater, both ex vivo and in vivo (all, P < 0.001). There were no significant differences in the readers' ratings of lesion conspicuity and lesion confidence in detecting hypodense liver lesions between SAFIRE and ADMIRE (P > 0.05). Only lesion conspicuity was superior with SAFIRE and ADMIRE compared with filtered back projection (all, P < 0.001). CONCLUSIONS: Noise texture deviation is a quantitative measure reflecting IR-specific artifacts and is reduced in CT images with ADMIRE compared with SAFIRE.
Authors: S Notohamiprodjo; R Stahl; M Braunagel; P M Kazmierczak; K M Thierfelder; K M Treitl; S Wirth; M Notohamiprodjo Journal: Eur Radiol Date: 2016-12-17 Impact factor: 5.315
Authors: Christian Booz; Jochen Nöske; Lukas Lenga; Simon S Martin; Ibrahim Yel; Katrin Eichler; Tatjana Gruber-Rouh; Nicole Huizinga; Moritz H Albrecht; Thomas J Vogl; Julian L Wichmann Journal: Eur Radiol Date: 2019-07-26 Impact factor: 5.315
Authors: Saravanabavaan Suntharalingam; Christian Mikat; Axel Wetter; Nika Guberina; Ahmed Salem; Philipp Heil; Michael Forsting; Kai Nassenstein Journal: Eur Radiol Date: 2018-01-10 Impact factor: 5.315
Authors: Thomas Sartoretti; Damien Racine; Victor Mergen; Lisa Jungblut; Pascal Monnin; Thomas G Flohr; Katharina Martini; Thomas Frauenfelder; Hatem Alkadhi; André Euler Journal: Diagnostics (Basel) Date: 2022-02-18
Authors: Bibi Martens; Joris G A Bosschee; Sander M J Van Kuijk; Cécile R L P N Jeukens; Maikel T H Brauer; Joachim E Wildberger; Casper Mihl Journal: PLoS One Date: 2022-04-07 Impact factor: 3.240