Enhancement of human plasma glucosylceramide assay sensitivity using delipidized plasma.

Kefei Zheng1, Allena Ji1, Lee Lee Chung1, Kerry Culm-Merdek1, Hanlan Liu1, Susan Richards1, Crystal Sung1.   

Abstract

Glucosylceramide (GL-1) level in human has been considered as a surrogate biomarker for enzyme replacement and substrate reduction therapies (ERT and SRT) for Gaucher and Fabry patients. Due to the high endogenous level of GL-1 in human plasma, it is difficult to achieve the analytical sensitivity of plasma GL-1 below the normal endogenous level (1.7 μg/mL to 6.6 μg/mL) when using the standard addition method and regular plasma matrix for standard curve. A high sensitivity plasma GL-1 assay with LLOQ at 0.1 μg/mL was developed and validated using delipidized plasma so that patient plasma concentrations that are below normal reference range can be measured accurately. The normal reference range was established from 120 healthy donors using this developed new method. Twenty-three Fabry patient plasma samples including baseline and post-investigation drug treatment samples were measured. All post-treatment samples showed GL-1 concentration below 2.0 μg/mL, indicating the utility of the reported high sensitivity assay using delipidized plasma for monitoring the plasma GL-1 biomarker level in patients.

Entities:  

Keywords:  Delipidized plasma; Globotriaosylceramide; Glucosylceramide; Liquid chromatography–tandem mass spectrometry (LC/MS/MS); Sensitivity; Standard addition method

Year:  2016        PMID: 27547732      PMCID: PMC4978213          DOI: 10.1016/j.ymgmr.2016.07.004

Source DB:  PubMed          Journal:  Mol Genet Metab Rep        ISSN: 2214-4269


Introduction

Gaucher disease and Fabry disease are lysosomal storage disorders. The two diseases are caused by deficiency of the catabolic enzyme β-glucocerebrosidase and α-galactosidase A (EC 3.2.1.22) [1], respectively. Both enzyme deficiency leads to a systematic accumulation of glucocerebroside (GL-1, also known as glucosylceramide) and globotriasylceramide (GL-3, also known as ceramide trihexoside, CTH, or Gb3) in blood and various organ tissues. These metabolic defect causes a painful neuropathy, angiokertomas, cardiac and renal failure, and cerebrovascular injury [2], [3], [4], [5], [6]. In the Fabry SRT clinical trial, very low plasma GL-1 levels were observed post treatment in patients, suggesting a 20-time more sensitive plasma GL-1 analytical method than the original plasma method with LLOQ of 2.0 μg/mL is needed. In the article, we reported a high sensitivity GL-1 assay using delipidized human plasma as the surrogate matrix of standards. Normal human plasma GL-1 reference range (n = 120) was established using this high sensitivity GL-1 assay. Twenty-three Fabry patient samples were analyzed and results showed the assay suitable for monitoring plasma GL-1 levels at low concentration.

Materials and methods

Glucosylceramide (GL-1) and Internal Standard (IS), N-C18:0 galactosylceramide-D35, (perdeuterated, C18:0 fatty acid), were purchased from Matreya (Pleasant Gap, PA). Delipidized plasma/serum was purchased from Golden West Biologicals, Inc. (Temecula, CA). Human plasma is delipidized using silica to remove the lipids. The product is then depth filtered, diafiltered, and 0.2 um filtered and filled. The sample extraction method was modified from the previous GL-1 method published in our laboratory but used delipidized human plasma as standard curve matrix [7]. Briefly, 50 μL plasma in a 96-wel plate was extracted with chloroform: methanol solution (2:1, v/v) containing internal standard. The bottom organic phase was transferred, evaporated, and reconstituted with chloroform. The extracted GL-1 in chloroform was then loaded onto a C18 based solid phase extraction cartridge (LiChrolut RP-18, 500 mg, Merck, VWR #: 48219-244), washed with chloroform, and eluted with acetone:methanol solvent (9:1, v/v). The final eluent was then dried and reconstituted with the mobile phase for LC/MS/MS analysis. The LC/MS/MS condition was the same as the GL-1 method reported [7]. Chromatographic separation was achieved using a hydrophilic interaction liquid chromatography (HILIC) column at 40 °C (XBridge™ HILIC column, 3.5 μm, 2.1 × 50 mm, Waters Corporation, Milford, MA) with an isocratic mobile phase of 95% Methanol with 2 mM Ammonium Acetate and 0.1% Formic Acid on a Waters Acquity UPLC system. The triple quadrupole Sciex API-4000 mass spectrometer was operated at positive electrospray ionization mode in multiple reaction monitoring (MRM) mode. The 7 isoforms and IS were monitored at below MS/MS transitions: 700.8 → 520.7 for C16:0 GL-1; 729.3 → 549.8 for C18:0 GL-1; 756.9 → 576.9 for C20:0 GL-1; 785.1 → 604.9 for C22:0 GL-1; 798.9 → 618.9 for C23:0 GL-1; 811.0 → 631.1 for C24:1 GL-1; 812.9 → 632.8 for C24:0 GL-1; 764.0 → 583.9 for IS N-C18:0 galactosylceramide-d35. The assay linear range was from 0.1 to 20 μg/mL. The ratio of the total peak area of each GL-1 isoform to peak area of internal standard was plotted against GL-1 concentration by MultiQuant™ software. Twenty three K2EDTA human plasma samples were obtained from 4 Fabry patients who received an investigational substrate reduction therapy drug treatment from Week 0 to Week 18. Patient informed consent for biomarker plasma GL-1 was provided.

Results and discussions

This high sensitivity GL-1 assay using delipidized plasma was validated. The results demonstrated that the method was precise and accurate, and met bioanalytical analysis industrial acceptance criteria. The linear range of the method was 0.1 to 20 μg/mL and extraction recovery was 68.4% for GL-1 and 73.2% for IS, respectively. In original normal plasma method, the recovery for GL-1 and IS was 84.1% and 69.1%, respectively. The slope comparison of standard curve in regular human plasma and delipidized human plasma showed a very similar slope, which demonstrated the delipdized plasma can replace human plasma and eliminated the interference of the endogenous GL-1 level in the blank matrix. In a side by side comparison experiment, the slope is 0.79893 for normal plasma and 0.80936 for delipidized plasma. The difference is 1.3%. Also, all 7 lots of delipidized plasma have consistent slopes, with %CV of 1.9%. The relative matrix effect was evaluated using one lot of delipidized plasma and human plasma from six individual healthy donors. The matrix effect precision (% CV) and accuracy (% Bias) were acceptable for both individual normal plasma and delipidized plasma pool. The normal reference range of plasma GL-1 was evaluated and varied from 1.7 to 6.7 μg/mL (n = 120) using the high sensitivity method, and from 1.7 μg/mL to 6.6 μg/mL (n = 100) using regular plasma GL-1 method (Fig. 1A). These data showed two methods gave very similar reference ranges and were in agreement with literature [2], in which GL-1 levels were determined in plasma samples obtained from 28 human healthy subjects through liquid-liquid extraction followed by LC/MS/MS analysis. For the 4 patients in the Fabry SRT trial week 0 to week 18, 19 out of 23 patient samples showed GL-1 concentrations below 2.0 μg/mL. As shown in Fig. 1B, all four patients had GL-1 concentration dropped below 2 μg/mL at 4 weeks post treatment in SRT trial.
Fig. 1

(A) Comparison of high sensitivity GL-1 assay (n = 120) vs. current human plasma assay (n = 100) using different normal plasma samples (B) Patient GL-1 Concentration after Dosing in SRT Trial.

Standard addition approach is commonly used to quantify biomarkers that contain high endogenous level in the human samples [8], [9], [10] in order to minimize matrix effect difference between standard curve and patient samples. However, it is technically challenging to develop a method with an LLOQ less than the normal reference range of the endogenous analyte present in the blank plasma (standard zero). Alternatively, isotope labeled analyte can be used for standard curve preparation [11]. However, obtaining stable labeled total GL-1 could be costly. Delipidized plasma without endogenous GL-1 level is a better choice for standard curve matrix to enhance the sensitivity. The surrogate matrices should mimic regular plasma characteristics during extraction. The surrogate matrices like human serum albumin in phosphate buffer saline, as well as artificial plasma were tried and showed significant difference in slopes comparing to regular human plasma. The delipidized plasma mimicked regular human plasma in the current reported method, which produced a similar slope as measured in regular human plasma for GL-1 analysis. In summary, the high sensitivity GL-1 assay was successfully developed and validated for its intended use to measure GL-1 in human plasma samples. Use of delipidized plasma as the blank matrix provided a much more sensitive LLOQ for monitoring GL-1 decrease in Fabry patients during an investigational substrate reduction therapy clinical trial.
  9 in total

1.  Improved management of lysosomal glucosylceramide levels in a mouse model of type 1 Gaucher disease using enzyme and substrate reduction therapy.

Authors:  John Marshall; Kerry Anne McEachern; Wei-Lien Chuang; Elizabeth Hutto; Craig S Siegel; James A Shayman; Greg A Grabowski; Ronald K Scheule; Diane P Copeland; Seng H Cheng
Journal:  J Inherit Metab Dis       Date:  2010-03-25       Impact factor: 4.982

2.  Liquid chromatography-tandem mass spectrometry quantification of globotriaosylceramide in plasma for long-term monitoring of Fabry patients treated with enzyme replacement therapy.

Authors:  Thomas P Roddy; Bryant C Nelson; Crystal C C Sung; Shaparak Araghi; Dennis Wilkens; X Kate Zhang; John J Thomas; Susan M Richards
Journal:  Clin Chem       Date:  2004-10-28       Impact factor: 8.327

3.  Mass spectrometric quantification of glucosylsphingosine in plasma and urine of type 1 Gaucher patients using an isotope standard.

Authors:  Mina Mirzaian; Patrick Wisse; Maria J Ferraz; Henrik Gold; Wilma E Donker-Koopman; Marri Verhoek; Herman S Overkleeft; Rolf G Boot; Gertjan Kramer; Nick Dekker; Johannes M F G Aerts
Journal:  Blood Cells Mol Dis       Date:  2015-01-17       Impact factor: 3.039

4.  Elevated plasma glucosylsphingosine in Gaucher disease: relation to phenotype, storage cell markers, and therapeutic response.

Authors:  Nick Dekker; Laura van Dussen; Carla E M Hollak; Herman Overkleeft; Saskia Scheij; Karen Ghauharali; Mariëlle J van Breemen; Maria J Ferraz; Johanna E M Groener; Mario Maas; Frits A Wijburg; Dave Speijer; Anna Tylki-Szymanska; Pramod K Mistry; Rolf G Boot; Johannes M Aerts
Journal:  Blood       Date:  2011-08-25       Impact factor: 22.113

5.  A rapid and quantitative LC-MS/MS method to profile sphingolipids.

Authors:  Max Scherer; Kerstin Leuthäuser-Jaschinski; Josef Ecker; Gerd Schmitz; Gerhard Liebisch
Journal:  J Lipid Res       Date:  2010-03-12       Impact factor: 5.922

6.  A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

Authors:  Allena Ji Ji; Haixing Wang; Enida Ziso-Qejvanaj; Kefei Zheng; Lee Lee Chung; Timothy Foley; Wei-Lien Chuang; Susan Richards; Crystal Sung
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

7.  HPLC for simultaneous quantification of total ceramide, glucosylceramide, and ceramide trihexoside concentrations in plasma.

Authors:  Johanna E M Groener; Ben J H M Poorthuis; Sijmen Kuiper; Mariette T J Helmond; Carla E M Hollak; Johannes M F G Aerts
Journal:  Clin Chem       Date:  2007-03-01       Impact factor: 8.327

Review 8.  Gaucher disease and Fabry disease: new markers and insights in pathophysiology for two distinct glycosphingolipidoses.

Authors:  Maria J Ferraz; Wouter W Kallemeijn; Mina Mirzaian; Daniela Herrera Moro; Andre Marques; Patrick Wisse; Rolf G Boot; Lianne I Willems; H S Overkleeft; J M Aerts
Journal:  Biochim Biophys Acta       Date:  2013-11-13

9.  Urinary globotriaosylceramide excretion correlates with the genotype in children and adults with Fabry disease.

Authors:  Christiane Auray-Blais; Denis Cyr; Aimé Ntwari; Michael L West; Josanne Cox-Brinkman; Daniel G Bichet; Dominique P Germain; Rachel Laframboise; Serge B Melançon; Tracy Stockley; Joe T R Clarke; Régen Drouin
Journal:  Mol Genet Metab       Date:  2007-11-26       Impact factor: 4.797

  9 in total
  3 in total

Review 1.  Contribution of tandem mass spectrometry to the diagnosis of lysosomal storage disorders.

Authors:  Monique Piraud; Magali Pettazzoni; Pamela Lavoie; Séverine Ruet; Cécile Pagan; David Cheillan; Philippe Latour; Christine Vianey-Saban; Christiane Auray-Blais; Roseline Froissart
Journal:  J Inherit Metab Dis       Date:  2018-03-19       Impact factor: 4.982

Review 2.  Recent advances in the mass spectrometric analysis of glycosphingolipidome - A review.

Authors:  Rodell C Barrientos; Qibin Zhang
Journal:  Anal Chim Acta       Date:  2020-05-24       Impact factor: 6.911

3.  Assessment of Target Engagement in a First-in-Human Trial with Sinbaglustat, an Iminosugar to Treat Lysosomal Storage Disorders.

Authors:  Martine Gehin; Meggane Melchior; Richard W D Welford; Patricia N Sidharta; Jasper Dingemanse
Journal:  Clin Transl Sci       Date:  2020-11-10       Impact factor: 4.689

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.