| Literature DB >> 27547267 |
Kaori Shintani-Ishida1, Yasuhiro Kakiuchi1, Hiroshi Ikegaya1.
Abstract
The toxicological detection of the new synthetic cathinone 4'-methyl-α-pyrrolidinohexanophenone (MPHP) in urine samples has been impossible, because much of MPHP is metabolized before its excretion into urine. In this study, we successfully quantified unmetabolized MPHP in urine of an autopsy case using a sensitive method by liquid chromatography-time-of-flight-mass spectrometry. The quantification method showed good linearity in the range of 1.00-100 ng/mL, and the limit of detection was 0.5 ng/mL in human urine. In the autopsy case, the concentrations of MPHP in urine, plasma, and liver tissue samples were determined to be 60.1, 32.9 ng/mL, and 63.1 ng/g, respectively.Entities:
Keywords: 4′-Methyl-α-pyrrolidinohexanophenone; Human urine; LC–TOF-MS; Liquid chromatography–time-of-flight-mass spectrometry; MPHP; Synthetic cathinone
Year: 2016 PMID: 27547267 PMCID: PMC4971032 DOI: 10.1007/s11419-016-0307-z
Source DB: PubMed Journal: Forensic Toxicol ISSN: 1860-8965 Impact factor: 4.096
Fig. 1Total ion current chromatogram (a), mass spectra of the precursor ion (b), and fragment ions (c) of a peak with a retention time of 3.63 min obtained from the deceased’s urine by liquid chromatography–time-of-flight-mass spectrometry (LC–TOF-MS). d shows the disconnection sites of 4′-carboxy-α-pyrrolidinohexanophenone predicted in molecular structure analysis for the full-spectrum of the fragment ions (c)
Molecular structure analyses with the fragment pattern of a target ion obtained from the deceased’s urine sample
| Fragment mass (Da) | Theoretical mass (Da) | Scorea |
|---|---|---|
| 149.0244 | 149.0239 | 1.0 |
| 140.1442 | 140.1439 | 1.0 |
| 135.0452 | 135.0446 | 1.5 |
aAn index of the energy required for disconnecting the bond
Fig. 2Extracted ion/total ion current chromatogram (a), mass spectra of the precursor ion (b) and fragment ions (c) of a peak with a retention time of 7.05 min obtained from the deceased’s urine (left panels) and 4′-methyl-α-pyrrolidinohexanophenone reference standard together with an internal standard 4′-methoxy-α-pyrrolidinopropiophenone (MeOPPP) (right panels) by LC–TOF-MS. XIC extracted ion chromatogram at m/z 260.202 ± 0.010; TIC total ion current chromatograms; asterisk peak of the internal standard MeOPPP
Intraday recovery, precision, and accuracy data for determination of 4′-methyl-α-pyrrolidinohexanophenone (MPHP) in urine (n = 5)
| Spiked concentration | Recovery | Precision | Accuracy |
|---|---|---|---|
| 1.0 | 95.6 | 9.9 | −8.5 |
| 100 | 104 | 5.9 | −5.8 |
RSD relative standard deviation, RE relative error
Concentrations of MPHP and relative amounts of 4′-carboxy-α-pyrrolidinohexanophenone (4′-carboxy-PHP) in the urine, plasma, and liver samples of the deceased
| Urine | Plasma | Liver | |
|---|---|---|---|
| MPHP | 60.1 ng/ml | 32.9 ng/ml | 63.1 ng/g |
| 4 | 970 | 35.2 | 25.5 |