Semi-continuous, real-time monitoring of protein biomarker using a recyclable surface plasmon resonance sensor.

Dong-Hyung Kim1, Il-Hoon Cho2, Ji-Na Park1, Sung-Ho Paek1, Hyun-Mo Cho3, Se-Hwan Paek4.   

Abstract

Although label-free immunosensors based on, for example, surface plasmon resonance (SPR) provide advantages of real-time monitoring of the analyte concentration, its application to routine clinical analysis in a semi-continuous manner is problematic because of the high cost of the sensor chip. The sensor chip is in most cases regenerated by employing an acidic pH. However, this causes gradual deterioration of the activity of the capture antibody immobilized on the sensor surface. To use sensor chips repeatedly, we investigated a novel surface modification method that enables regeneration of the sensor surface under mild conditions. We introduced a monoclonal antibody (anti-CBP Ab) that detects the conformational change in calcium binding protein (CBP) upon Ca2+ binding (>1mM). To construct a regenerable SPR-based immunosensor, anti-CBP Ab was first immobilized on the sensor surface, and CBP conjugated to the capture antibody (specific for creatine kinase-MB isoform (CK-MB); CBP-CAb) then bound in the presence of Ca2+. A serum sample was mixed with the detection antibody to CK-MB, which generated an SPR signal proportional to the analyte concentration. After each analysis, the sensor surface was regenerated using medium (pH 7) without Ca2+, and then adding fresh CBP-CAb in the presence of Ca2+ for the subsequent analysis. Analysis of multiple samples using the same sensor was reproducible at a rate >98.7%. The dose-response curve was linear for 1.75-500.75ng/mL CK-MB, with an acceptable coefficient of variation of <8.8%. The performance of the immunosensor showed a strong correlation with that of the Pathfast reference system (R2>96%), and exhibited analytical stability for 1 month. To our knowledge, this is the first report of a renewal of a sensor surface with fresh antibody after each analysis, providing high consistency in the assay during a long-term use (e.g., a month at least).
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acute myocardial infarction markers; Companion diagnostics; Conformation change-sensitive antibody; Label-free sensor regeneration; Semi-continuous immunosensor

Mesh:

Substances:

Year:  2016        PMID: 27545847     DOI: 10.1016/j.bios.2016.08.035

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Real-Time Monitoring of a Protein Biomarker.

Authors:  Claudio Parolo; Andrea Idili; Gabriel Ortega; Andrew Csordas; Alex Hsu; Netzahualcóyotl Arroyo-Currás; Qin Yang; Brian Scott Ferguson; Jinpeng Wang; Kevin W Plaxco
Journal:  ACS Sens       Date:  2020-07-13       Impact factor: 7.711

Review 2.  Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics.

Authors:  Marcin Drozd; Sylwia Karoń; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-05-29       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.