Literature DB >> 27543526

Validation of non-invasive arterial pressure monitoring during carotid endarterectomy.

J F Heusdens1, S Lof2, C W A Pennekamp2, J C Specken-Welleweerd2, G J de Borst2, W A van Klei1, L van Wolfswinkel1, R V Immink3.   

Abstract

BACKGROUND: Patients undergoing carotid endarterectomy require strict arterial blood pressure (BP) control to maintain adequate cerebral perfusion. In this study we tested whether non-invasive beat-to-beat Nexfin finger BP (BPfin) can replace invasive beat-to-beat radial artery BP (BPrad) in this setting.
METHODS: In 25 consecutive patients (median age 71 yr) scheduled for carotid endarterectomy and receiving general anaesthesia, BPfin and BPrad were monitored simultaneously and ipsilaterally during the 30-min period surrounding carotid artery cross-clamping. Validation was guided by the standard set by the Association for the Advancement of Medical Instrumentation (AAMI), which considers a BP monitor adequate when bias (precision) is <5 (8) mm Hg, respectively.
RESULTS: BPfin vs BPrad bias (precision) was -3.3 (10.8), 6.1 (5.7) and 3.5 (5.2) mm Hg for systolic, diastolic, and mean BP, respectively. One subject was excluded due to a poor quality BP curve. In another subject, mean BPfin overestimated mean BPrad by 13.5 mm Hg.
CONCLUSION: Mean BPfin could be considered as an alternative for mean BPrad during a carotid endarterectomy, based on the AAMI criteria. In 23 of 24 patients, the use of mean BPfin would not lead to decisions to adjust mean BPrad values outside the predefined BP threshold. CLINICALTRIALSGOV: NCT01451294.
© The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  Nexfin; carotid endarterectomy; measurement techniques, arterial pressure; non-invasive continuous arterial pressure measurement

Mesh:

Year:  2016        PMID: 27543526     DOI: 10.1093/bja/aew268

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  10 in total

1.  The prevalence of cardiovascular autonomic neuropathy and its influence on post induction hemodynamic variables in patients with and without diabetes; A prospective cohort study.

Authors:  Jorinde A W Polderman; Nicolaas H Sperna Weiland; Michel H Klaver; Judy Biginski; Marijn Horninge; Markus W Hollmann; J Hans DeVries; Rogier V Immink; Benedikt Preckel; Jeroen Hermanides
Journal:  PLoS One       Date:  2018-11-26       Impact factor: 3.240

2.  Performance of the Hypotension Prediction Index with non-invasive arterial pressure waveforms in non-cardiac surgical patients.

Authors:  Kamal Maheshwari; Sai Buddi; Zhongping Jian; Jos Settels; Tetsuya Shimada; Barak Cohen; Daniel I Sessler; Feras Hatib
Journal:  J Clin Monit Comput       Date:  2020-01-27       Impact factor: 2.502

3.  Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation.

Authors:  Sang-Wook Lee; Sangho Lee; Hyungtae Kim; Yun-Jong Kim; Mihyeon Kim; Jeong-Hyun Choi
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

4.  Hypotension Prediction Index with non-invasive continuous arterial pressure waveforms (ClearSight): clinical performance in Gynaecologic Oncologic Surgery.

Authors:  Luciano Frassanito; Pietro Paolo Giuri; Francesco Vassalli; Alessandra Piersanti; Alessia Longo; Bruno Antonio Zanfini; Stefano Catarci; Anna Fagotti; Giovanni Scambia; Gaetano Draisci
Journal:  J Clin Monit Comput       Date:  2021-10-07       Impact factor: 1.977

5.  Noninvasive cardiac output measurements are inaccurate in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation.

Authors:  Musashi Yahagi; Kyuma Omi; Takuma Maeda
Journal:  Korean J Anesthesiol       Date:  2021-10-20

6.  The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study.

Authors:  Marije Wijnberge; Björn van der Ster; Alexander P J Vlaar; Markus W Hollmann; Bart F Geerts; Denise P Veelo
Journal:  J Clin Med       Date:  2022-07-14       Impact factor: 4.964

7.  Non-invasive continuous blood pressure monitoring using the ClearSight system for pregnant women at high risks of post-partum hemorrhage: comparison with invasive blood pressure monitoring during cesarean section.

Authors:  Takuya Misugi; Takashi Juri; Koichi Suehiro; Kohei Kitada; Yasushi Kurihara; Mie Tahara; Akihiro Hamuro; Akemi Nakano; Masayasu Koyama; Takasi Mori; Daisuke Tachibana
Journal:  Obstet Gynecol Sci       Date:  2022-06-27

8.  Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery.

Authors:  Tadashi Tanioku; Akari Yoshida; Yuichi Aratani; Keisuke Fujii; Tomoyuki Kawamata
Journal:  BMC Anesthesiol       Date:  2020-07-20       Impact factor: 2.217

9.  Noninvasive continuous monitoring versus intermittent oscillometric measurements for the detection of hypotension during digestive endoscopy.

Authors:  Anh-Dao Phan; Arthur Neuschwander; Guillaume Perrod; Gabriel Rahmi; Christophe Cellier; Bernard Cholley
Journal:  PLoS One       Date:  2020-10-02       Impact factor: 3.240

10.  The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study.

Authors:  Leonie M M Fassaert; Joost D J Plate; Jan Westerink; Rogier V Immink; Gert J de Borst
Journal:  Am J Hypertens       Date:  2022-02-01       Impact factor: 2.689

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.