Literature DB >> 27542821

Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

Karin Bachmann1, Annette Pn Kutter2, Rahel Jud Schefer1, Charlotte Marly-Voquer2, Nadja Sigrist1.   

Abstract

Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P <0.05). Furthermore, pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, ionised calcium and anion gap exceeded the recommended TEa. Conclusions and relevance Assessment of actual and standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27542821     DOI: 10.1177/1098612X16663269

Source DB:  PubMed          Journal:  J Feline Med Surg        ISSN: 1098-612X            Impact factor:   2.015


  3 in total

1.  First report of Cytauxzoon sp. infection in domestic cats in Switzerland: natural and transfusion-transmitted infections.

Authors:  Alice Nentwig; Marina L Meli; Johanna Schrack; Iris M Reichler; Barbara Riond; Corinne Gloor; Judith Howard; Regina Hofmann-Lehmann; Barbara Willi
Journal:  Parasit Vectors       Date:  2018-05-10       Impact factor: 3.876

2.  Hyperinsulinemia/euglycemia and intravenous lipid emulsion therapy for the management of severe amlodipine toxicosis in a cat.

Authors:  Audrey E Tinsman; Tara J Bellis
Journal:  Clin Case Rep       Date:  2021-12-07

3.  Severity of Ionized Hypercalcemia and Hypocalcemia Is Associated With Etiology in Dogs and Cats.

Authors:  Michelle Coady; Daniel J Fletcher; Robert Goggs
Journal:  Front Vet Sci       Date:  2019-08-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.