Literature DB >> 27539415

Characterization and application of droplet spray ionization for real-time reaction monitoring.

Hong Zhang1, Na Li2, Xiao-di Li2, Jie Jiang2, Dan-Dan Zhao2, Hong You1.   

Abstract

RATIONALE: The ionization source for real-time reaction monitoring has attracted tremendous interest in recent years. We have previously reported a reliable approach in which droplet spray ionization (DSI) was used for monitoring chemical reactions in real-time. Herein, we systematically investigated the characterization and application of DSI for real-time reaction monitoring.
METHODS: Analyte ions are generated by loading a sample solution onto a corner of a microscope cover glass positioned in front of the MS inlet and applying a high voltage to the sample. The tolerance to positioning, solvent effect, spray angle and spray time were investigated. Extension to real-time monitoring of macromolecule reactions was also demonstrated by the charge state change of cytochrome c in the presence of acetic acid.
RESULTS: The corner could be positioned within an area of approximately 10 × 6 × 5 mm (x, y, z) in front of the MS inlet. The broad polarities of solvents from methanol to PhF were suitable for DSI. It featured monitoring real-time changes in reactions on the time scale of seconds to minutes. A real-time charge state change of cytochrome c was captured.
CONCLUSIONS: DSI-MS features ease of use, durability of the spray platform and reusability of the ion source. Eliminating the need for a sample transport capillary, DSI opens a new avenue for the in situ analysis and real-time monitoring of short-lived key reaction intermediates even at subsecond dead times.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27539415     DOI: 10.1002/rcm.7642

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Substrate-Coated Illumination Droplet Spray Ionization: Real-Time Monitoring of Photocatalytic Reactions.

Authors:  Hong Zhang; Na Li; Dandan Zhao; Jie Jiang; Hong You
Journal:  J Am Soc Mass Spectrom       Date:  2017-05-17       Impact factor: 3.109

2.  Activating peroxymonosulfate by halogenated and methylated quinones: performance and mechanism.

Authors:  Hong Zhang; Lina Qiao; Jing He; Na Li; Dongmei Zhang; Kai Yu; Hong You; Jie Jiang
Journal:  RSC Adv       Date:  2019-08-30       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.