Literature DB >> 27538936

[Cochlear implant fitting strategies].

U Hoppe1, T Liebscher2, J Hornung2.   

Abstract

Cochlear implant (CI) fitting is the technical adjustment of a CI processor to the individual needs of a subject. Fitting comprises the choice of stimulation strategy and determination of the lower and upper stimulation levels for the individual. This electrical dynamic range defines the stimulation range for the real-time functioning of the CI system. All of the CI manufacturers provide a large set of parameters which have to be optimized for proper hearing and speech comprehension. As a consequence of the widening of indication criteria for CIs and lowering the age of implantation for children, the fitting process has changed dramatically over the years. This includes replacement of behavioral responses by other data from objective electrophysiologic measures and from expert knowledge. Recent developments aim to structure and automatize the CI fitting process. This reduces the time requirement for CI fitting and leads to fast settings which can be tested in the real-time situation. This review provides an overview of state-of-the-art fitting procedures and recent developments for fitting strategies. These will be discussed with respect to practicability and quality assurance.

Entities:  

Keywords:  Child; Cochlear implantation; Health care quality assurance; Prosthesis fitting; Rehabilitation

Mesh:

Year:  2017        PMID: 27538936     DOI: 10.1007/s00106-016-0226-7

Source DB:  PubMed          Journal:  HNO        ISSN: 0017-6192            Impact factor:   1.284


  27 in total

1.  [Where should rehabilitation after cochlear implant management take place? Ambulatory vs. inpatient care].

Authors:  R Laszig
Journal:  HNO       Date:  2000-11       Impact factor: 1.284

2.  Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants.

Authors:  K Stephan; K Welzl-Müller
Journal:  Audiology       Date:  2000 Jan-Feb

3.  Speech perception in nucleus CI24M cochlear implant users with processor settings based on electrically evoked compound action potential thresholds.

Authors:  Guido F Smoorenburg; Christina Willeboer; Johannes E van Dijk
Journal:  Audiol Neurootol       Date:  2002 Nov-Dec       Impact factor: 1.854

Review 4.  Electric-acoustic stimulation of the auditory system: a review of the first decade.

Authors:  Christoph A von Ilberg; Uwe Baumann; Jan Kiefer; Jochen Tillein; Oliver F Adunka
Journal:  Audiol Neurootol       Date:  2011-05-24       Impact factor: 1.854

5.  Evaluation of the 'Fitting to Outcomes eXpert' (FOX®) with established cochlear implant users.

Authors:  Andreas Buechner; Bart Vaerenberg; Dzemal Gazibegovic; Martina Brendel; Geert De Ceulaer; Paul Govaerts; Thomas Lenarz
Journal:  Cochlear Implants Int       Date:  2014-06-20

6.  [Speech perception with hearing aids in comparison to pure-tone hearing loss].

Authors:  U Hoppe; A Hast; T Hocke
Journal:  HNO       Date:  2014-06       Impact factor: 1.284

Review 7.  [Intraoperative audiological-technical diagnostics during cochlear implant surgery].

Authors:  T Wesarg; S Arndt; A Aschendorff; R Laszig; S Zirn
Journal:  HNO       Date:  2014-10       Impact factor: 1.284

8.  [Unilateral deafness and cochlear implantation: audiological diagnostic evaluation and outcomes].

Authors:  S Arndt; R Laszig; A Aschendorff; R Beck; C Schild; F Hassepass; G Ihorst; S Kroeger; P Kirchem; T Wesarg
Journal:  HNO       Date:  2011-05       Impact factor: 1.284

9.  [Cochlear implant for malformations of the inner ear].

Authors:  A Aschendorff; R Laszig; W Maier; R Beck; C Schild; R Birkenhäger; T Wesarg; S Kröger; S Arndt
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

10.  Cochlear implant programming: a global survey on the state of the art.

Authors:  Bart Vaerenberg; Cas Smits; Geert De Ceulaer; Elie Zir; Sally Harman; N Jaspers; Y Tam; Margaret Dillon; Thomas Wesarg; D Martin-Bonniot; L Gärtner; Sebastian Cozma; Julie Kosaner; Sandra Prentiss; P Sasidharan; Jeroen J Briaire; Jane Bradley; J Debruyne; R Hollow; Rajesh Patadia; Lucas Mens; K Veekmans; R Greisiger; E Harboun-Cohen; Stéphanie Borel; Dayse Tavora-Vieira; Patrizia Mancini; Helen Cullington; Amy Han-Chi Ng; Adam Walkowiak; William H Shapiro; Paul J Govaerts
Journal:  ScientificWorldJournal       Date:  2014-02-04
View more
  2 in total

Review 1.  Cochlear Implantation.

Authors:  Stefan Dazert; Jan Peter Thomas; Andreas Loth; Thomas Zahnert; Timo Stöver
Journal:  Dtsch Arztebl Int       Date:  2020-10-09       Impact factor: 5.594

2.  [Impact of CI use and CI fitting on speech production in very early cochlear-implanted infants].

Authors:  C Glaubitz; T Liebscher; U Hoppe
Journal:  HNO       Date:  2021-05       Impact factor: 1.284

  2 in total