Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.

S Gunsoy1, M Ulusoy1.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of this study was to evaluate the internal and marginal fit of chrome cobalt (Co-Cr) crowns were fabricated with laser sintering, computer-aided design (CAD) and computer-aided manufacturing, and conventional methods.
MATERIALS AND METHODS: Polyamide master and working models were designed and fabricated. The models were initially designed with a software application for three-dimensional (3D) CAD (Maya, Autodesk Inc.). All models were fabricated models were produced by a 3D printer (EOSINT P380 SLS, EOS). 128 1-unit Co-Cr fixed dental prostheses were fabricated with four different techniques: Conventional lost wax method, milled wax with lost-wax method (MWLW), direct laser metal sintering (DLMS), and milled Co-Cr (MCo-Cr). The cement film thickness of the marginal and internal gaps was measured by an observer using a stereomicroscope after taking digital photos in ×24.
RESULTS: Best fit rates according to mean and standard deviations of all measurements was in DLMS both in premolar (65.84) and molar (58.38) models in μm. A significant difference was found DLMS and the rest of fabrication techniques (P < 0.05). No significant difference was found between MCo-CR and MWLW in all fabrication techniques both in premolar and molar models (P > 0.05).
CONCLUSION: DMLS was best fitting fabrication techniques for single crown based on the results.The best fit was found in marginal; the larger gap was found in occlusal.All groups were within the clinically acceptable misfit range.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27538553     DOI: 10.4103/1119-3077.188699

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  3 in total

1.  Comparative Evaluation of the Marginal Adaptation of Cast Ni-Cr Copings, Direct Metal Laser Sintering Co-Cr Copings, and Computer-aided Design and Computer-aided Manufacturing Zr Copings: An In-vitro Study.

Authors:  Lokanathanbalaji Doddy; Sesha Reddy; Sashideepth Reddy; Narendra R
Journal:  Cureus       Date:  2019-11-07

2.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

Review 3.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.