| Literature DB >> 27532112 |
Thais Caldara Mussi1, Rodrigo Gobbo Garcia2, Marcos Roberto Gomes Queiroz2, Gustavo Caserta Lemos3, Ronaldo Hueb Baroni1.
Abstract
OBJECTIVE: To evaluate the diagnostic efficacy of transrectal ultrasonography (US) bi¬opsy with imaging fusion using multiparametric (mp) magnetic resonance imaging (MRI) in patients with suspicion of prostate cancer (PCa), with an emphasis on clini¬cally significant tumors according to histological criteria.Entities:
Keywords: Magnetic Resonance Imaging; Prostate; Prostatic Neoplasms
Mesh:
Substances:
Year: 2016 PMID: 27532112 PMCID: PMC5066885 DOI: 10.1590/S1677-5538.IBJU.2015.0204
Source DB: PubMed Journal: Int Braz J Urol ISSN: 1677-5538 Impact factor: 1.541
mpMRI prostate protocol.
| Sequence | Thickness (mm) | Spacing (mm) |
|---|---|---|
| T2 FSE axial with fat sat | 6 | 1 |
| T1 GRE axial “in-phase” and “opposed-phase” | 6 | 1 |
| T2 FSE sagittal | 3 | 0.3 |
| T2 FSE axial high resolution | 3 | 0.3 |
| T2 FSE 3D coronal volumetric isotropic | 1 | - |
| Diffusion (b50, 400 and 800) | 3 | 0.3 |
| T1 GRE VIBE pre-contrast | 3 | - |
| T1 GRE VIBE dynamic post-contrast | 3 | - |
| T1 GRE VIBE post-contrast pelvis | 4 | - |
Figure 1MpMRI example of a suspicion lesion on the right lobe of peripheral zone of the prostate: A) a round lesion on T2 weighted-image; B) ADC map shows diffusion restriction; C) dynamic-contrast-imaging with hypervascularization and D) washout (blue line). Patient received US/MRI-guided biopsy where we can see the lesion on MRI (E and F) and in real time on US (G), helping to target the lesion (H).
Figure 2A suspicious lesion on mpMRI (images B and D) submitted to a US-MRI fusion biopsy. The lesion was not seen on US (arrow in A) and the biopsy was performed based on mpMRI (arrow in C). The biopsy result was Gleason 3+4 in all tree fragments of this area.
Suspicion level on mpMRI and biopsy results.
| Biopsy | ||||
|---|---|---|---|---|
| Negative | Positive non-significant | Positive significant | ||
| Suspicion on mpMRI | Very low | 1 | 0 | 0 |
| Low | 10 | 4 | 3 | |
| Equivocal | 42 | 10 | 16 | |
| Moderate | 21 | 6 | 31 | |
| High | 5 | 2 | 38 | |
p-value <0.001
Suspicion level on mpMRI and biopsy results according clinical relevance.
| Biopsy | |||
|---|---|---|---|
| Negative + positive clinically non-significant | Positive clinically-significant | ||
| Suspicion on mpMRI | Very low | 1 | 0 |
| Low | 14 | 3 | |
| Equivocal | 52 | 16 | |
| Moderate | 27 | 31 | |
| High | 7 | 38 | |
p-value <0.001
Figure 3Frequency of patients in each Gleason score value in correlation with level of suspicion on mpMRI (n=110).