Literature DB >> 27531494

Accuracy assessment of atlantoaxial pedicle screws assisted by a novel drill guide template.

Lianghai Jiang1,2, Liang Dong3, Mingsheng Tan4,5, Feng Yang1, Ping Yi1, Xiangsheng Tang1.   

Abstract

INTRODUCTION: Posterior atlantoaxial pedicle screw fixation is an effective technique for atlantoaxial instability (AAI). However, because of the complex anatomy of the cranio-cervical junction, it remains challenging to insert atlantoaxial pedicle screw precisely and safely. A novel drill guide template was designed for atlantoaxial pedicle screw placement in this study. The purpose of this study is to quantitatively evaluate the accuracy of atlantoaxial pedicle screw placement using the novel drill guide template.
MATERIALS AND METHODS: Between June 2014 and September 2015, 32 consecutive patients with AAI were included. Using the Mimics v17.0 and 3-matic v9.0 softwares, a novel drill guide template with two location holes and guide rods was designed. All patients underwent posterior atlantoaxial pedicle screw fixation assisted by the novel drill guide template. After surgery, the entry point and directions of actual and ideal screw trajectories were measured and compared.
RESULTS: All patients underwent surgery successfully assisted by the novel drill guide template. A total of 128 atlantoaxial pedicle screws were placed for 32 AAI patients. Postoperative CT scans showed two screws in atlas deviated medially from the pedicle cortex and entered the spinal canal about 1 mm but without symptoms. For both atlas and axis, there were no significant differences in entry point or directions between the ideal and actual screw trajectories (P > 0.05). Significant differences were found in preoperative and postoperative Japanese Orthopaedic Association score and Visual Analogue Score (P < 0.001).
CONCLUSIONS: It is feasible to use the novel drill guide template for atlantoaxial pedicle screw placement. The accuracy of screw placement assisted by the novel template is high. More studies are needed to confirm the efficacy of this template.

Entities:  

Keywords:  Atlantoaxial instability; Drill guide template; Pedicle screw; Rapid prototyping

Mesh:

Year:  2016        PMID: 27531494     DOI: 10.1007/s00402-016-2530-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Atlantoaxial dislocation and os odontoideum in two identical twins: perspectives on etiology.

Authors:  Xiangsheng Tang; Mingsheng Tan; Ping Yi; Feng Yang; Qingying Hao
Journal:  Eur Spine J       Date:  2017-05-15       Impact factor: 3.134

2.  [Accuracy analysis and clinical application of the progressive navigation template system to assist atlas-axial pedicle screw placement].

Authors:  Chao Wu; Jiayan Deng; Lun Tan; Xu Lin; Dechao Yuan
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-02-15

3.  Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement.

Authors:  Xiao-Long Chen; Ya-Fen Xie; Jian-Xin Li; Wu Wu; Guan-Nan Li; Hui-Jing Hu; Xiao-Yun Wang; Zhao-Jian Meng; Yue-Feng Wen; Wen-Hua Huang
Journal:  PLoS One       Date:  2019-04-02       Impact factor: 3.240

4.  Endoscopic transnasal anterior release and posterior reduction without odontoidectomy for irreducible atlantoaxial dislocation.

Authors:  Xiangsheng Tang; Xinjie Wu; Mingsheng Tan; Ping Yi; Feng Yang; Qingying Hao
Journal:  J Orthop Surg Res       Date:  2019-05-06       Impact factor: 2.359

5.  Power-Tool Use in Orthopaedic Surgery: Iatrogenic Injury, Its Detection, and Technological Advances: A Systematic Review.

Authors:  Matthew C A Arnold; Sarah Zhao; Ruben J Doyle; Jonathan R T Jeffers; Oliver R Boughton
Journal:  JB JS Open Access       Date:  2021-11-19

6.  Treatment of Upper Cervical Spinal Cord Injury (Unstable C1-C2) by Direct Visualization and Nailing Technique and the Advantages of Early MRI.

Authors:  Jamal Alshorman; Lian Zeng; Yulong Wang; Fengzhao Zhu; Kaifang Chen; Sheng Yao; Xirui Jing; Yanzhen Qu; Tingfang Sun; Xiaodong Guo
Journal:  J Healthc Eng       Date:  2021-09-29       Impact factor: 2.682

7.  Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template.

Authors:  Xingwei Pu; Chunshan Luo; Tinsheng Lu; Shudan Yao; Qiling Chen
Journal:  Clinics (Sao Paulo)       Date:  2018-07-19       Impact factor: 2.365

8.  The effectiveness and safety of 3-dimensional printed composite guide plate for atlantoaxial pedicle screw: A retrospective study.

Authors:  Fei Wang; Chang-Hong Li; Zhi-Bin Liu; Zhang-Jian Hua; Yong-Jin He; Jun Liu; Yan-Xiong Liu; Xiao-Qian Dang
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.889

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.