Literature DB >> 27530512

The Correlation of Two Cerebral Saturation Monitors With Jugular Bulb Oxygen Saturation in Children Undergoing Cardiopulmonary Bypass for Congenital Heart Surgery.

Aymen N Naguib1,2, Peter D Winch1,2, Roby Sebastian1,2, Daniel Gomez2, Luisa Guzman3, Julie Rice1, Dmitry Tumin1, Mark Galantowicz2, Joseph D Tobias1,2.   

Abstract

BACKGROUND: Near-infrared spectroscopy (NIRS) is a noninvasive monitoring technique that measures regional cerebral oxygen saturation (rSO2).
OBJECTIVES: The primary aim was to compare the output of 2 NIRS-based cerebral oximetry devices, FORESIGHT (CAS Medical Systems Inc, Branford, Connecticut) and INVOS (Covidien, Boulder, Colorado), to venous oxygen saturations from the jugular venous bulb at cannulation and decannulation of the superior vena cava (SVC). Secondary objectives included evaluating correlations of cerebral saturation, as measured by the NIRS devices, with mean arterial blood pressure (MAP), measured by an invasive arterial line, and end-tidal CO2 (ETCO2).
METHODS: Near-infrared spectroscopy, MAP, and ETCO2 data were collected at 13 defined events during each case when hemodynamic instability was expected. At SVC cannulation and decannulation, a 0.1 mL sample of blood was collected from the jugular bulb by the surgeon using a long angiocatheter. The oxygen saturation of these blood samples was measured using an AVOX device and compared with contemporaneous readings from the NIRS probes. Mixed-effects linear regression was used to correlate MAP or ETCO2 with cerebral oxygen saturation (by NIRS) at each time point.
RESULTS: Children undergoing cardiopulmonary bypass for congenital heart surgery (n = 34) were enrolled in the study. At SVC cannulation, both INVOS ( r = .78) and FORESIGHT ( r = .59) were correlated with AVOX data at P < .001, although the correlation with INVOS was significantly stronger ( P = .003). At SVC decannulation, INVOS ( r = .68; P < .001) and FORESIGHT ( r = .60; P < .001) were similarly correlated with jugular venous rSO2. Correlations of rSO2 (by NIRS) with MAP and ETCO2 levels were stronger than correlations between rSO2 change and change in MAP or ETCO2.
CONCLUSION: INVOS correlated more strongly than FORESIGHT with the jugular bulb rSO2 at SVC cannulation but may have underestimated oxygen saturation at low rSO2 values. Data from both NIRS devices were correlated with MAP and ETCO2 over the case duration.

Entities:  

Keywords:  anesthesia; brain tissue oxygen tension; clinical research; hemodynamic monitoring; monitoring

Mesh:

Year:  2016        PMID: 27530512     DOI: 10.1177/0885066616663649

Source DB:  PubMed          Journal:  J Intensive Care Med        ISSN: 0885-0666            Impact factor:   3.510


  6 in total

1.  Correlation between Regional Cerebral Saturation and Invasive Cardiac Index Monitoring after Heart Transplantation Surgery.

Authors:  Awni M Al-Subu; Christoph P Hornik; Ira M Cheifetz; Andrew J Lodge; George Ofori-Amanfo
Journal:  J Pediatr Intensive Care       Date:  2018-06-11

2.  The Effect of Autologus Blood Priming on Cerebral Oximetry in Congenital Cardiac Surgery Patients.

Authors:  Ashley Hodge; Apryl Cohen; Peter Winch; Dmitry Tumin; Jeffrey Burnside; Todd Ratliff; Mark Galantowicz; Aymen Naguib
Journal:  J Extra Corpor Technol       Date:  2017-09

Review 3.  Neuroprotective Anesthesia Regimen and Intensive Management for Pediatric Cardiac Surgery with Cardiopulmonary Bypass: a Review and Initial Experience.

Authors:  Jyrson Guilherme Klamt; Walter Villela de Andrade Vicente; Luis Vicente Garcia; Fabio Carmona; João Abrão; Antônio Carlos Menardi; Paulo Henrique Manso
Journal:  Braz J Cardiovasc Surg       Date:  2017 Nov-Dec

4.  Regional Cerebral Oximetry as an Indicator of Acute Brain Injury in Adults Undergoing Veno-Arterial Extracorporeal Membrane Oxygenation-A Prospective Pilot Study.

Authors:  Imad Khan; Mehboob Rehan; Gunjan Parikh; Christopher Zammit; Neeraj Badjatia; Daniel Herr; Zachary Kon; Charles Hogue; Michael Mazzeffi
Journal:  Front Neurol       Date:  2018-11-23       Impact factor: 4.003

5.  Effects of Apolipoprotein E Polymorphism on Cerebral Oxygen Saturation After Traumatic Brain Injury.

Authors:  Zhimin Wu; Senjie Xiong; Xiaochuan Sun; Quanhong Shi; Wei Dan; Yan Zhan; Yanfeng Xie; Li Jiang
Journal:  Front Neurol       Date:  2020-11-12       Impact factor: 4.003