Literature DB >> 27527248

The added value of intraoperative CT scanner and screw navigation in displaced posterior wall acetabular fracture with articular impaction.

A Sebaaly1, G Riouallon2, M Zaraa1, P Jouffroy1.   

Abstract

Posterior wall with transverse acetabular fractures represents the most common type of acetabular fractures and is generally associated with poorer outcomes. This is caused by improper visualization of the fragments leading to imperfect reductions. Navigation in pelvic and acetabular trauma is reserved nowadays to non-displaced or mildly displaced fractures. To add to that, perioperative control of reduction is difficult using the conventional X-ray. The described 3D imaging method allowed proper reduction control. On the other hand, screw navigation of acetabular screws enabled better control of screw position as well as screw placement in otherwise inaccessible zones. In conclusion, peroperative 3D imaging and screw navigation optimize fracture reduction promoting better radiological and functional results.
Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Impaction; Intraoperative imaging; Navigation; Posterior wall acetabular fracture

Mesh:

Year:  2016        PMID: 27527248     DOI: 10.1016/j.otsr.2016.07.005

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  4 in total

1.  Clinical impact of intraoperative cone beam tomography and navigation for displaced acetabular fractures: a comparative study at medium-term follow-up.

Authors:  Maroun Rizkallah; Amer Sebaaly; Elias Melhem; Pierre-Emmanuel Moreau; Peter Upex; Pomme Jouffroy; Guillaume Riouallon
Journal:  Int Orthop       Date:  2021-05-22       Impact factor: 3.075

2.  Does the use of intraoperative CT scan improve outcomes in Orthopaedic surgery? A systematic review and meta-analysis of 871 cases.

Authors:  Vishal Kumar; Vishnu Baburaj; Sandeep Patel; Siddhartha Sharma; Raju Vaishya
Journal:  J Clin Orthop Trauma       Date:  2021-05-15

3.  Intraoperative assessment of reduction and implant placement in acetabular fractures-limitations of 3D-imaging compared to computed tomography.

Authors:  Holger Keil; Nils Beisemann; Marc Schnetzke; Sven Yves Vetter; Benedict Swartman; Paul Alfred Grützner; Jochen Franke
Journal:  J Orthop Surg Res       Date:  2018-04-10       Impact factor: 2.359

4.  The accuracy of gap and step-off measurements in acetabular fracture treatment.

Authors:  A M L Meesters; K Ten Duis; J Kraeima; H Banierink; V M A Stirler; P C R Wouters; J P P M de Vries; M J H Witjes; F F A IJpma
Journal:  Sci Rep       Date:  2021-09-14       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.