Literature DB >> 27525519

Stress Distribution in Obliquely Inserted Orthodontic Miniscrews Evaluated by Three-Dimensional Finite-Element Analysis.

Shingo Kuroda, Masahide Inoue, Hee-Moon Kyung, Jan Harm Koolstra, Eiji Tanaka.   

Abstract

PURPOSE: The purpose of this study was to evaluate the influence of placement angle and force direction on the initial stability of orthodontic miniscrews using a three-dimensional finite element model that approximates the real interface between the screw and surrounding bone.
MATERIALS AND METHODS: Three-dimensional finite element models with 6-mm-long and 1.4-mm-diameter titanium miniscrews were used. Four insertion angles, ranging from 0 degrees (perpendicular to the bone surface) to 45 degrees, were examined. A load of 2 N was applied to the center of the screw head in four directions (upward, downward, and on the right and left sides).
RESULTS: At the same insertion angle, the stresses on the miniscrews were highest in downward force applications, while they were the lowest in upward force applications. This means that with upward traction, stresses are more evenly distributed on the surface of the miniscrew. An analysis of the principal stress distribution in surrounding bone showed that compressive and tensile stresses increased with the angle of insertion up to 30 degrees. For larger insertion angles, the increase almost vanished.
CONCLUSION: An obliquely inserted miniscrew and its surrounding tissues generally provide sufficient anchorage for 2 N of orthodontic loading, but care must be taken to avoid screw failure during placement and removal of obliquely placed miniscrews.

Year:  2016        PMID: 27525519     DOI: 10.11607/jomi.5061

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models.

Authors:  Takahiro Toriya; Toru Kitahara; Hiroto Hyakutake; Mitsugu Todo; Ichiro Takahashi
Journal:  Ann Biomed Eng       Date:  2022-09-27       Impact factor: 4.219

2.  A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone.

Authors:  Omar Nazal Auwer; Marwa Sameh Shamaa; Shaza Mohammad Hammad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

3.  Thread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis.

Authors:  Takuma Sakamaki; Keiichiro Watanabe; Akihiko Iwasa; Toru Deguchi; Shinya Horiuchi; Eiji Tanaka
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996