Literature DB >> 27524851

Using liquid crystal variable retarders for fast modulation of bias and shear direction in quantitative differential interference contrast (DIC) microscope.

Michael Shribak1.   

Abstract

Conventional DIC microscope shows the two-dimensional distribution of optical path length gradient encountered along the shear direction between two interfering beams. It is therefore necessary to rotate unknown objects in order to examine them at several orientations. We built new DIC beam shearing assembly, which allows the bias to be modulated and shear directions to be switched rapidly without any mechanically rotating the specimen or the prisms. The assembly consists of two standard DIC prisms with liquid crystal cell in between. Another liquid crystal cell is employed for modulating a bias. All components do not require a special design and are available on the market. We describe techniques for measuring parameters of DIC prisms and calibrating liquid crystal cells. One beam-shearing assembly is added to the illumination path and another one to the imaging path of standard microscope. Two sets of raw DIC images at the orthogonal shear directions and two or three different biases are captured and processed within a second. Then the quantitative image of optical path gradient distribution within a thin optical section is displayed on a computer screen. The obtained data are also used to compute the quantitative distribution of optical phase, which represents refractive index gradient or height distribution. It is possible to generate back the enhanced regular DIC images with any desired shear direction. New DIC microscope can be combined with other techniques, such as fluorescence and polarization microscopy.

Entities:  

Keywords:  Differential interference contrast (DIC) microscopy; dry mass; liquid crystal devices; live cell imaging; optical path gradient; quantitative phase imaging

Year:  2013        PMID: 27524851      PMCID: PMC4981344          DOI: 10.1117/12.2008243

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  14 in total

1.  Theoretical development and experimental evaluation of imaging models for differential-interference-contrast microscopy.

Authors:  C Preza; D L Snyder; J A Conchello
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-09       Impact factor: 2.129

2.  Differential interference contrast microscope with differential detection for optimizing image contrast.

Authors:  H Ooki; Y Iwasaki; J Iwasaki
Journal:  Appl Opt       Date:  1996-05-01       Impact factor: 1.980

3.  DIC image reconstruction on large cell scans.

Authors:  Bettina Heise; Alois Sonnleitner; Erich Peter Klement
Journal:  Microsc Res Tech       Date:  2005-04-15       Impact factor: 2.769

4.  Orientation-independent differential interference contrast microscopy and its combination with an orientation-independent polarization system.

Authors:  Michael Shribak; James LaFountain; David Biggs; Shinya Inouè
Journal:  J Biomed Opt       Date:  2008 Jan-Feb       Impact factor: 3.170

5.  Polarization-modulated differential-interference contrast microscopy with a variable retarder.

Authors:  G M Holzwarth; D B Hill; E B McLaughlin
Journal:  Appl Opt       Date:  2000-12-01       Impact factor: 1.980

6.  Reconstructing specimens using DIC microscope images.

Authors:  F Kagalwala; T Kanade
Journal:  IEEE Trans Syst Man Cybern B Cybern       Date:  2003

7.  Differential interference contrast microscope using photonic crystals for phase imaging and three-dimensional shape reconstruction.

Authors:  Laurent Fabre; Yoshihiko Inoue; Takafumi Aoki; Shojiro Kawakami
Journal:  Appl Opt       Date:  2009-03-01       Impact factor: 1.980

8.  Calibrating differential interference contrast microscopy with dual-focus fluorescence correlation spectroscopy.

Authors:  Claus B Müller; Kerstin Weiss; Walter Richtering; Anastasia Loman; Jöerg Enderlein
Journal:  Opt Express       Date:  2008-03-17       Impact factor: 3.894

9.  Sample-less calibration of the differential interference contrast microscope.

Authors:  Shalin B Mehta; Colin J R Sheppard
Journal:  Appl Opt       Date:  2010-05-20       Impact factor: 1.980

10.  Quantitative Carré differential interference contrast microscopy to assess phase and amplitude.

Authors:  Donald D Duncan; David G Fischer; Amanda Dayton; Scott A Prahl
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2011-06-01       Impact factor: 2.129

View more