Literature DB >> 27524043

Novel alkaline-reduced cuprous oxide/graphene nanocomposites for non-enzymatic amperometric glucose sensor application.

Siti Nur Akmar Mohd Yazid1, Illyas Md Isa2, Norhayati Hashim3.   

Abstract

This paper presents the fabrication of a highly sensitive and selective glucose sensor based on cuprous oxide/graphene nanocomposites-modified glassy carbon electrode (Cu2O/graphene/GCE). The Cu2O/graphene nanocomposites were synthesized based on a simple and straightforward chemical reduction process in alkaline aqueous solution using sodium carbonate as reductant. The size and shape of Cu2O nanoparticles on graphene sheets can be controlled by changing the amount of graphene oxide added during reaction. The electrochemical properties of Cu2O/graphene/GCE in 0.1M phosphate buffer solution were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. It was found that the pH, concentration of supporting electrolyte, and scan rate had very crucial effect on the sensitivity of prepared sensor towards glucose oxidation. At an applied potential of +0.50V, the Cu2O/graphene/GCE presented a high sensitivity of 1330.05μAmM(-1)cm(-2) and fast response (within 3s). The amperometric non-enzymatic glucose sensor developed had a linear relationship from 0.01mM to 3.0mM glucose and detection limit of 0.36μM. In the presence of ascorbic acid, uric acid, dopamine, chloride and citrate ion and other carbohydrates, the interferences were negligible. The proposed sensor was successfully applied for the determination of glucose concentration in real human blood samples.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Alkaline solution; Cu(2)O nanoparticles; Electrochemical; Glucose; Graphene

Mesh:

Substances:

Year:  2016        PMID: 27524043     DOI: 10.1016/j.msec.2016.06.006

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  2 in total

1.  Microwave-assisted synthesis of graphene modified CuO nanoparticles for voltammetric enzyme-free sensing of glucose at biological pH values.

Authors:  Faranak Foroughi; Mansour Rahsepar; Mohammad Jafar Hadianfard; Hasuck Kim
Journal:  Mikrochim Acta       Date:  2017-12-18       Impact factor: 5.833

2.  A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor.

Authors:  Sopit Phetsang; Duangruedee Khwannimit; Parawee Rattanakit; Narong Chanlek; Pinit Kidkhunthod; Pitchaya Mungkornasawakul; Jaroon Jakmunee; Kontad Ounnunkad
Journal:  Front Chem       Date:  2021-05-20       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.