Literature DB >> 27524036

In vitro and in vivo corrosion and histocompatibility of pure Mg and a Mg-6Zn alloy as urinary implants in rat model.

Shiying Zhang1, Yang Zheng2, Liming Zhang3, Yanze Bi2, Jianye Li3, Jiao Liu2, Youbin Yu3, Heqing Guo4, Yan Li5.   

Abstract

Pure Mg and a Mg-6wt.% Zn alloy were investigated as potential candidates for biodegradable implants for the urinary system. The in vitro corrosion behavior was studied by potentiodynamic polarization and immersion tests in simulated body fluid (SBF) at 37°C. The in vivo degradation and histocompatibility were examined through implantation into the bladders of Wistar rats. The alloying element Zn elevated the passivation potential and increased the cathodic current density. Both in vitro and in vivo degradation tests showed a faster corrosion rate for the Mg-6Zn alloy. Tissues stained with hematoxylin and eosin (HE) suggested that both pure Mg and Mg-6Zn alloy exhibited good histocompatibility in the bladder indwelling implantation and no differences between pure Mg and Mg-6Zn groups were found in bladder, liver and kidney tissues during the 2weeks implantation. Overall, this work presented instructive information on the degradation properties and histocompatibility of pure Mg and the Mg-6Zn alloy in the urinary system.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Degradation; In vivo histocompatibility; Magnesium alloy; Urinary implants

Mesh:

Substances:

Year:  2016        PMID: 27524036     DOI: 10.1016/j.msec.2016.06.017

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  7 in total

1.  MicroRNA-195 Activates Hepatic Stellate Cells In Vitro by Targeting Smad7.

Authors:  Li-Ying Song; Yu-Tao Ma; Cui-Fang Wu; Chun-Jiang Wang; Wei-Jin Fang; Shi-Kun Liu
Journal:  Biomed Res Int       Date:  2017-08-27       Impact factor: 3.411

2.  In vitro study of the inflammatory cells response to biodegradable Mg-based alloy extract.

Authors:  Liang Jin; Jing Wu; Guangyin Yuan; Tongxin Chen
Journal:  PLoS One       Date:  2018-03-14       Impact factor: 3.240

3.  Powder metallurgical Ti-Mg metal-metal composites facilitate osteoconduction and osseointegration for orthopedic application.

Authors:  Sihui Ouyang; Qianli Huang; Yong Liu; Zhengxiao Ouyang; Luxin Liang
Journal:  Bioact Mater       Date:  2018-12-11

4.  Monitoring and Assessing the Degradation Rate of Magnesium-Based Artificial Bone In Vitro Using a Wireless Magnetoelastic Sensor.

Authors:  Limin Ren; Kun Yu; Yisong Tan
Journal:  Sensors (Basel)       Date:  2018-09-12       Impact factor: 3.576

5.  Biological Assessment of Zn-Based Absorbable Metals for Ureteral Stent Applications.

Authors:  Devi Paramitha; Stéphane Chabaud; Stéphane Bolduc; Hendra Hermawan
Journal:  Materials (Basel)       Date:  2019-10-12       Impact factor: 3.623

6.  In vivo performance of a rare earth free Mg-Zn-Ca alloy manufactured using twin roll casting for potential applications in the cranial and maxillofacial fixation devices.

Authors:  Matthew S Dargusch; Nagasivamuni Balasubramani; Nan Yang; Sean Johnston; Yahia Ali; Gui Wang; Jeffrey Venezuela; Jiwon Carluccio; Cora Lau; Rachel Allavena; Daniel Liang; Karine Mardon; Qingsong Ye
Journal:  Bioact Mater       Date:  2021-10-23

7.  Biodegradation behavior of magnesium and ZK60 alloy in artificial urine and rat models.

Authors:  Shiying Zhang; Yanze Bi; Jianye Li; Zhenguo Wang; Jingmin Yan; Jiawang Song; Haibo Sheng; Heqing Guo; Yan Li
Journal:  Bioact Mater       Date:  2017-04-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.