Literature DB >> 27523995

Impedimetric immunosensor for detection of cardiovascular disorder risk biomarker.

Raju Khan1, Mintu Pal2, Alexey V Kuzikov3, Tanya Bulko3, Elena V Suprun3, Victoria V Shumyantseva3.   

Abstract

We report the construction and characterization of a novel, level free impedimetric immunosensor for rapid, sensitive and selective detection of myoglobin (Mb). Monoclonal anti-myoglobin (anti-Mb-IgG) antibody was immobilized on screen-printed multiwalled carbon nanotubes electrode for signal amplification without the need of natural enzymes. The fabrication of resulting immunosensor was extensively characterized by using scanning electron microscopy (SEM), fourier transform infrared (FT-IR) spectroscopy, cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Electrochemical impedance spectroscopy (EIS) technique offered a linear detection range (0.1-90ngmL(-1)) of myoglobin with sensitivity of 0.74kΩngmL(-1) (correlation coefficient, R(2)=0.97) and detection limit of 0.08ngmL(-1) (S/N=3). The mean percentage recovery of Mb in serum samples using this working biosensor is 97.33%. Furthermore, the proposed strategy can be a promising alternative for detection of Mb related cardiovascular disorders.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiovascular disease; Electrochemical impedance spectroscopy; Immunosensors; Myoglobin; Screen-printed multiwalled carbon nanotubes electrode

Mesh:

Substances:

Year:  2016        PMID: 27523995     DOI: 10.1016/j.msec.2016.05.107

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  7 in total

1.  An impedimetric bioaffinity sensing chip integrated with the long-range DC-biased AC electrokinetic centripetal vortex produced in a high conductivity solution.

Authors:  Ming-Jie Lin; Yen-Fu Liu; Ching-Chou Wu
Journal:  Biomicrofluidics       Date:  2018-07-06       Impact factor: 2.800

2.  Plastic antibodies tailored on quantum dots for an optical detection of myoglobin down to the femtomolar range.

Authors:  Ana Margarida Piloto; David S M Ribeiro; S Sofia M Rodrigues; Catarina Santos; João L M Santos; M Goreti F Sales
Journal:  Sci Rep       Date:  2018-03-21       Impact factor: 4.379

Review 3.  Carbon Nanomaterial Based Biosensors for Non-Invasive Detection of Cancer and Disease Biomarkers for Clinical Diagnosis.

Authors:  Tibor Pasinszki; Melinda Krebsz; Thanh Tran Tung; Dusan Losic
Journal:  Sensors (Basel)       Date:  2017-08-20       Impact factor: 3.576

Review 4.  Diagnostics Strategies with Electrochemical Affinity Biosensors Using Carbon Nanomaterials as Electrode Modifiers.

Authors:  Susana Campuzano; Paloma Yáñez-Sedeño; José M Pingarrón
Journal:  Diagnostics (Basel)       Date:  2016-12-26

5.  Structural and anionic effects of microcrystalline Zn-CPs on 4-nitrophenol sensing performances.

Authors:  Hyemin Lee; Min-Yeong Kim; Haeri Lee
Journal:  RSC Adv       Date:  2022-04-28       Impact factor: 4.036

6.  Label-Free, Highly Sensitive Electrochemical Aptasensors Using Polymer-Modified Reduced Graphene Oxide for Cardiac Biomarker Detection.

Authors:  Abhinav Sharma; Jyoti Bhardwaj; Jaesung Jang
Journal:  ACS Omega       Date:  2020-02-18

Review 7.  A review on impedimetric immunosensors for pathogen and biomarker detection.

Authors:  J Leva-Bueno; Sally A Peyman; P A Millner
Journal:  Med Microbiol Immunol       Date:  2020-04-03       Impact factor: 3.402

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.