Literature DB >> 27522514

Presence of an arterial line improves response to simulated hypotension and pulseless electrical activity.

Jonathan Lipps1, Andrew Goldberg2, Samuel DeMaria2, Yury Khelemsky2, Adam Levine2, Vedat Yildiz3, Bryan Mahoney4.   

Abstract

With pulseless electrical activity (PEA) emerging as one of the leading cardiac arrest arrhythmias, the rapid response and accurate diagnosis of PEA is essential to improve survival rates. Although the use of invasive blood pressure monitoring to more quickly detect changes in blood pressure is widespread, evidence for its use is largely anecdotal and placement is not without risk. This is a prospective, multi-center, randomized controlled trial involving 58 senior anesthesiology residents undergoing a simulation of intraoperative PEA using high-fidelity simulation. Of the total 58 participants, 28 subjects were randomized to invasive blood pressure monitoring and 30 to non-invasive blood pressure monitoring in order to investigate the effects of arterial line information on the response time of ACLS-trained anesthesiology residents. Response times of subjects in the group provided with invasive blood pressure monitoring were faster to palpate pulses (6.5 s faster, p = .0470), initiate chest compressions (17 s faster, p = .004), and administer 1 mg of epinephrine (21 s faster, p = .0005. The absolute number of pharmacologic interventions was increased in the group with invasive blood pressure monitoring (p = .020). These findings suggest that noninvasive blood pressure monitoring and other readily available monitors are not as powerful as invasive blood pressure monitoring in influencing decision-making during a PEA event. As there is currently no specific blood pressure at which the patient is considered to be in PEA, future studies are necessary to clarify the correlation between the arterial line tracing and the appropriate trigger for ACLS initiation.

Entities:  

Keywords:  Anesthesia; Arterial line; Cardiac arrest; Hypotension; Invasive monitoring; Simulation

Mesh:

Year:  2016        PMID: 27522514     DOI: 10.1007/s10877-016-9919-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  16 in total

1.  Indwelling arterial catheters in the intensive care unit: necessary and beneficial, or a harmful crutch?

Authors:  Allan Garland; Alfred F Connors
Journal:  Am J Respir Crit Care Med       Date:  2010-07-15       Impact factor: 21.405

Review 2.  Part 8: adult advanced cardiovascular life support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Authors:  Robert W Neumar; Charles W Otto; Mark S Link; Steven L Kronick; Michael Shuster; Clifton W Callaway; Peter J Kudenchuk; Joseph P Ornato; Bryan McNally; Scott M Silvers; Rod S Passman; Roger D White; Erik P Hess; Wanchun Tang; Daniel Davis; Elizabeth Sinz; Laurie J Morrison
Journal:  Circulation       Date:  2010-11-02       Impact factor: 29.690

Review 3.  Part 7: Adult Advanced Cardiovascular Life Support: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Authors:  Mark S Link; Lauren C Berkow; Peter J Kudenchuk; Henry R Halperin; Erik P Hess; Vivek K Moitra; Robert W Neumar; Brian J O'Neil; James H Paxton; Scott M Silvers; Roger D White; Demetris Yannopoulos; Michael W Donnino
Journal:  Circulation       Date:  2015-11-03       Impact factor: 29.690

4.  Peripheral pulse palpation: an unreliable physical sign.

Authors:  S Brearley; C P Shearman; M H Simms
Journal:  Ann R Coll Surg Engl       Date:  1992-05       Impact factor: 1.891

5.  Cardiopulmonary resuscitation quality: [corrected] improving cardiac resuscitation outcomes both inside and outside the hospital: a consensus statement from the American Heart Association.

Authors:  Peter A Meaney; Bentley J Bobrow; Mary E Mancini; Jim Christenson; Allan R de Caen; Farhan Bhanji; Benjamin S Abella; Monica E Kleinman; Dana P Edelson; Robert A Berg; Tom P Aufderheide; Venu Menon; Marion Leary
Journal:  Circulation       Date:  2013-06-25       Impact factor: 29.690

6.  Association between Intraoperative Hypotension and Hypertension and 30-day Postoperative Mortality in Noncardiac Surgery.

Authors:  Terri G Monk; Michael R Bronsert; William G Henderson; Michael P Mangione; S T John Sum-Ping; Deyne R Bentt; Jennifer D Nguyen; Joshua S Richman; Robert A Meguid; Karl E Hammermeister
Journal:  Anesthesiology       Date:  2015-08       Impact factor: 7.892

7.  Variation of arterial and central venous catheter use in United States intensive care units.

Authors:  Hayley B Gershengorn; Allan Garland; Andrew Kramer; Damon C Scales; Gordon Rubenfeld; Hannah Wunsch
Journal:  Anesthesiology       Date:  2014-03       Impact factor: 7.892

8.  Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults.

Authors:  Gregory Nuttall; Jennifer Burckhardt; Anita Hadley; Sarah Kane; Daryl Kor; Mary Shirk Marienau; Darrell R Schroeder; Kathryn Handlogten; Gregory Wilson; William C Oliver
Journal:  Anesthesiology       Date:  2016-03       Impact factor: 7.892

9.  Time to administration of epinephrine and outcome after in-hospital cardiac arrest with non-shockable rhythms: retrospective analysis of large in-hospital data registry.

Authors:  Michael W Donnino; Justin D Salciccioli; Michael D Howell; Michael N Cocchi; Brandon Giberson; Katherine Berg; Shiva Gautam; Clifton Callaway
Journal:  BMJ       Date:  2014-05-20

Review 10.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

View more
  1 in total

1.  Dynamic changes in arterial blood gas during cardiopulmonary resuscitation in out-of-hospital cardiac arrest.

Authors:  Seok-In Hong; June-Sung Kim; Youn-Jung Kim; Won Young Kim
Journal:  Sci Rep       Date:  2021-11-30       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.