Literature DB >> 27522407

VOCs emission rate estimate for complicated industrial area source using an inverse-dispersion calculation method: A case study on a petroleum refinery in Northern China.

Wei Wei1, Zhaofeng Lv2, Gan Yang2, Shuiyuan Cheng3, Yue Li2, Litao Wang4.   

Abstract

This study aimed to apply an inverse-dispersion calculation method (IDM) to estimate the emission rate of volatile organic compounds (VOCs) for the complicated industrial area sources, through a case study on a petroleum refinery in Northern China. The IDM was composed of on-site monitoring of ambient VOCs concentrations and meteorological parameters around the source, calculation of the relationship coefficient γ between the source's emission rate and the ambient VOCs concentration by the ISC3 model, and estimation of the actual VOCs emission rate from the source. Targeting the studied refinery, 10 tests and 8 tests were respectively conducted in March and in June of 2014. The monitoring showed large differences in VOCs concentrations between background and downwind receptors, reaching 59.7 ppbv in March and 248.6 ppbv in June, on average. The VOCs increases at receptors mainly consisted of ethane (3.1%-22.6%), propane (3.8%-11.3%), isobutane (8.5%-10.2%), n-butane (9.9%-13.2%), isopentane (6.1%-12.9%), n-pentane (5.1%-9.7%), propylene (6.1-11.1%) and 1-butylene (1.6%-5.4%). The chemical composition of the VOCs increases in this field monitoring was similar to that of VOCs emissions from China's refineries reported, which revealed that the ambient VOCs increases were predominantly contributed by this refinery. So, we used the ISC3 model to create the relationship coefficient γ for each receptor of each test. In result, the monthly VOCs emissions from this refinery were calculated to be 183.5 ± 89.0 ton in March and 538.3 ± 281.0 ton in June. The estimate in June was greatly higher than in March, chiefly because the higher environmental temperature in summer produced more VOCs emissions from evaporation and fugitive process of the refinery. Finally, the VOCs emission factors (g VOCs/kg crude oil refined) of 0.73 ± 0.34 (in March) and 2.15 ± 1.12 (in June) were deduced for this refinery, being in the same order with previous direct-measurement results (1.08-2.65 g VOCs/kg crude oil refined). An inverse-dispersion calculation method was applied to estimate VOCs emission rate for a petroleum refinery, being 183.5 ton/month (March) and 538.3 ton/month (June).
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Emission rate; Industrial area source; Inverse-dispersion calculation method; Petroleum refinery; VOCs

Mesh:

Substances:

Year:  2016        PMID: 27522407     DOI: 10.1016/j.envpol.2016.07.062

Source DB:  PubMed          Journal:  Environ Pollut        ISSN: 0269-7491            Impact factor:   8.071


  1 in total

1.  Speciated VOCs emission estimate for a typical petrochemical manufacturing plant in China using inverse-dispersion calculation method.

Authors:  Wei Wei; Yating Wang; Gan Yang; Li Yue; Shuiyuan Cheng
Journal:  Environ Monit Assess       Date:  2018-07-07       Impact factor: 2.513