Literature DB >> 27515316

Adherence to guidelines in monitoring amiodarone-induced thyroid dysfunction.

Chun-Jui Huang1,2, Chi-Lung Tseng3,4,2, Chia-Huei Chu5,2, De-Feng Huang6,2, Chin-Chou Huang7,2, Liang-Yu Lin1,2.   

Abstract

RATIONALE, AIMS AND
OBJECTIVES: Baseline thyroid function testing and regular follow-up of thyroid function under amiodarone usage was recommended by guidelines. Little is known about the status of amiodarone monitoring in real-world clinical care in Taiwan. The objective was to determine the rate of thyroid monitoring and to assess the clinical and physicians' characteristics associated with adequate monitoring in a tertiary referral centre for arrhythmia.
METHODS: We reviewed the medical records of patients receiving amiodarone during the period 2008-2009 at Taipei Veterans General Hospital. The rate of baseline and follow-up thyroid function monitoring during amiodarone therapy were calculated. Factors associated with guideline adherence to monitoring were analysed.
RESULTS: Among the 1319 enrolled cases, 36.4% (n = 480) underwent baseline thyroid function testing and 1.1% (n = 15) received measurement of anti-thyroid peroxidase antibody before amiodarone initiation. Regular follow up of thyroid function under amiodarone usage occurred in only 8.6% (n = 114) of cases. Baseline thyroid function was more likely to be present in patients of younger age (P < 0.001), female sex (P = 0.01), and in those who received amiodarone therapy from cardiologists (P < 0.001) or electrophysiologists (P < 0.001) with fewer years of service (P < 0.001). Upon multivariate analysis, only physicians' expertise (cardiologist versus non-cardiologist, OR = 5.67, 95% CI: 2.44-13.16) and years of service (OR = 0.97, 95% CI: 0.95-0.998) were significantly associated with adequate thyroid monitoring.
CONCLUSIONS: The rate of thyroid monitoring with amiodarone therapy had been suboptimal. Strategies to enhance guideline adherence are needed.
© 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  amiodarone; guideline; hyperthyroidism; hypothyroidism; monitor; thyroid

Mesh:

Substances:

Year:  2016        PMID: 27515316     DOI: 10.1111/jep.12619

Source DB:  PubMed          Journal:  J Eval Clin Pract        ISSN: 1356-1294            Impact factor:   2.431


  2 in total

1.  Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study.

Authors:  Bander Ahmed Albassam; Nouf Mohammed Almutairi; Sarah Fahad Aldosari; Hind Saleh Almodaimegh
Journal:  J Pharm Policy Pract       Date:  2020-08-18

2.  Adherence to Monitoring Guidelines of Amiodarone Adverse Reactions.

Authors:  Ophir Lavon; Ron Goldman
Journal:  Health Serv Res Manag Epidemiol       Date:  2019-04-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.