Literature DB >> 27514445

A Prospective, Randomized Study of an Expanded Polytetrafluoroethylene Stent Graft versus Balloon Angioplasty for In-Stent Restenosis in Arteriovenous Grafts and Fistulae: Two-Year Results of the RESCUE Study.

Abigail Falk1, Ivan D Maya2, Alexander S Yevzlin3.   

Abstract

PURPOSE: To assess the safety and efficacy of an expanded polytetrafluoroethylene stent graft versus balloon angioplasty for the treatment of in-stent restenosis in the venous outflow of hemodialysis access grafts and fistulae.
MATERIALS AND METHODS: Two hundred seventy-five patients were randomized at 23 US sites to stent-graft placement or percutaneous transluminal angioplasty (PTA). Primary study endpoints were access circuit primary patency (ACPP) at 6 months and safety through 30 days; secondary endpoints were evaluated through 24 months.
RESULTS: ACPP at 6 months was significantly higher in the stent-graft group (18.6%) versus the PTA group (4.5%; P < .001), and freedom from safety events (30 days) was comparable (stent graft, 96.9%; PTA, 96.4%; P = .003 for noninferiority). The separation in ACPP survival curves remained through 12 months (stent graft, 6.2%; PTA, 1.5%). Treatment area primary patency (TAPP) was superior for the stent-graft group (66.4%) versus the PTA group (12.3%) at 6 months (P < .001), with a survivorship difference in favor of stent-graft placement maintained through 24 months (stent graft, 15.6%; PTA, 2.2%). ACPP and TAPP for the stent-graft group were better than those for the PTA group when compared within central and peripheral vein subgroups (P < .001). In central veins, TAPP was 13.6% in the stent-graft group versus 4.3% in the PTA group at 24 months (P < .001).
CONCLUSIONS: Stent-graft use provided better ACPP and TAPP than PTA when treating in-stent restenosis in patients receiving dialysis with arteriovenous grafts and fistulae.
Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27514445     DOI: 10.1016/j.jvir.2016.06.014

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  4 in total

1.  New therapeutic options provided by off-label deployment of stent graft for tailored arteriovenous access salvage: Two cases.

Authors:  Riccardo Corti; Pietro Quaretti; Franco Galli; Lorenzo Paolo Moramarco; Nicola Cionfoli; Giovanni Leati; Riccardo Corbetta; Matteo Tozzi
Journal:  SAGE Open Med Case Rep       Date:  2017-11-14

Review 2.  Stent Graft Outcomes in Dialysis Circuits: A Review of Clinical Trials and Literature.

Authors:  Austin J Pourmoussa; Ashwin M Mahendra; Constantino S Peña; Alex Powell; Brian J Schiro; Raul Herrera; Barry T Katzen; Govindarajan Narayanan; Andrew S Niekamp; Ripal T Gandhi
Journal:  Semin Intervent Radiol       Date:  2022-02-18       Impact factor: 1.513

3.  Stent graft deployment in haemodialysis fistula: patency rates in partially thrombosed aneurysm and residual thrombi.

Authors:  José García-Medina; Ana B Maldonado-Cárceles; Juan J García-Alfonso; Julián J Árense-Gonzalo; Alberto M Torres-Cantero
Journal:  Clin Kidney J       Date:  2020-02-10

4.  First Clinical Results of the Merit WRAPSODY™ Cell-Impermeable Endoprosthesis for Treatment of Access Circuit Stenosis in Haemodialysis Patients.

Authors:  James Gilbert; Jason Rai; David Kingsmore; John Skousen; Nikolaos Ptohis
Journal:  Cardiovasc Intervent Radiol       Date:  2021-09-12       Impact factor: 2.740

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.