Literature DB >> 27513905

Intraocular Pressure Outcomes Following Transscleral Diode Cyclophotocoagulation Using Long and Short Duration Burns.

Sultan Alzuhairy1, Abdullah Albahlal, Ibrahim Aljadaan, Ohoud Owaidhah, Sami Al Shahwan, Earl Randy Craven, Ahmed Mousa, Deepak P Edward.   

Abstract

PURPOSE: The purpose of this study was to compare outcomes of transscleral diode cyclophotocoagulation using short duration (SD) versus longer duration (LD) treatment. PATIENTS AND METHODS: Data were collected retrospectively on patients with glaucoma who underwent cyclophotocoagulation with LD (4000 ms) treatment with variable power ≤1000 mW versus SD using 1500 ms with variable power ≤2000 mW. The outcome measures included: intraocular pressure (IOP) at 12 months, decrease in number of antiglaucoma medications, complications and visual acuity (VA) at the final follow-up visit.
RESULTS: There were 71 patients and 70 patients in the SD and LD groups, respectively. The mean IOP±SD pretreatment baseline was 33±10 versus 36±10 mm Hg for SD and LD groups, respectively (P>0.05). At 1 year postoperatively, the IOP decreased significantly in both groups (16.7 vs. 17.4 mm Hg for SD and LD, respectively; P<0.0001). This decrease in IOP was comparable between groups (P=0.5). The average number of IOP lowering medications were 2.5 and 2.9 at baseline in the SD and LD groups, respectively, and decreased to 1.3 in both groups (P=0.83). The mean LogMAR VA decreased significantly from 1.87 at baseline to 1.96 at 1 year in the SD group (P=0.276), and 2.03 to 2.3 (P≤0.001) in the LD group, this change was comparable (0.19; P=0.075) between the 2 groups. Complications were also comparable.
CONCLUSIONS: Both LD and SD burns during cyclophotocoagulation effectively lowered IOP at 1 year. Neither treatment resulted in a greater reduction of IOP. LD treatment appeared to result in a decrease in VA and greater postoperative inflammation.

Entities:  

Mesh:

Year:  2016        PMID: 27513905     DOI: 10.1097/IJG.0000000000000503

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  5 in total

1.  Immediate IOP elevation after transscleral cyclophotocoagulation.

Authors:  M R Razeghinejad; A Hamid; M H Nowroozzadeh
Journal:  Eye (Lond)       Date:  2017-04-07       Impact factor: 3.775

2.  Transscleral Diode Laser Cyclophotocoagulation: A Comparison of Slow Coagulation and Standard Coagulation Techniques.

Authors:  Eric Rh Duerr; Mohamed S Sayed; Stephen Moster; Timothy Holley; Jin Peiyao; Elizabeth A Vanner; Richard K Lee
Journal:  Ophthalmol Glaucoma       Date:  2018-08-25

3.  Randomized comparative trial of diode laser transscleral cyclophotocoagulation versus Ahmed glaucoma valve for neovascular glaucoma in Chinese - a pilot study.

Authors:  Bonnie Nga Kwan Choy; Jimmy Shiu Ming Lai; Jane Chun Chun Yeung; Jonathan Cheuk Hung Chan
Journal:  Clin Ophthalmol       Date:  2018-12-07

4.  Comparison of the safety and efficacy of triple sequential therapy and transscleral cyclophotocoagulation for neovascular glaucoma in the angle-closure stage.

Authors:  Ying Hong; Yuntao Hu; Hongliang Dou; Changguan Wang; Chun Zhang; Zhizhong Ma
Journal:  Sci Rep       Date:  2018-05-04       Impact factor: 4.379

5.  Effectiveness and Safety of Long Duration versus Short Duration Diode Laser Transscleral Cyclophotocoagulation.

Authors:  Jonathan Cheuk-Hung Chan; Shing Chuen Chow; Jimmy Shiu-Ming Lai
Journal:  Clin Ophthalmol       Date:  2020-01-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.