Development, validation, and application of a method for selected avermectin determination in rural waters using high performance liquid chromatography and fluorescence detection.

Maria Augusta Travassos Lemos1, Camila Alves Matos2, Michele Fabri de Resende1, Rachel Bardy Prado3, Raquel Andrade Donagemma2, Annibal Duarte Pereira Netto4.   

Abstract

Avermectins (AVM) are macrocyclic lactones used in livestock and agriculture. A quantitative method of high performance liquid chromatography with fluorescence detection for the determination of eprinomectin, abamectin, doramectin and ivermectin in rural water samples was developed and validated. The method was employed to study samples collected in the Pito Aceso River microbasin, located in the Bom Jardim municipality, Rio de Janeiro State, Brazil. Samples were extracted by solid phase extraction using a polymeric stationary phase, the eluted fraction was re-concentrated under a gentle N2 flow and derivatized to allow AVM determination using liquid chromatography with fluorescence detection. The excitation and emission wavelengths of the derivatives were 365 and 470nm, respectively, and a total chromatographic run of 12min was achieved. Very low limits of quantification (22-58ngL(-1)) were found after re-concentration using N2. Recovery values varied from 85.7% to 119.2% with standard deviations between 1.2% and 10.2%. The validated method was applied in the determination of AVM in 15 water samples collected in the Pito Aceso River microbasin, but most of them were free of AVM or showed only trace levels of these compounds, except for a sample that contained doramectin (9.11µgL(-1)). The method is suitable for routine analysis with satisfactory recovery, sensitivity, and selectivity.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Avermectins; HPLC-Fluo; High performance of liquid chromatography; Macrocyclic lactones; Pesticides; Rural water contamination

Mesh:

Substances:

Year:  2016        PMID: 27513222     DOI: 10.1016/j.ecoenv.2016.07.038

Source DB:  PubMed          Journal:  Ecotoxicol Environ Saf        ISSN: 0147-6513            Impact factor:   6.291


  2 in total

1.  A highly sensitive octopus-like azobenzene fluorescent probe for determination of abamectin B1 in apples.

Authors:  Zhenlong Guo; YiFei Su; Kexin Li; MengYi Tang; Qiang Li; Shandong Xu
Journal:  Sci Rep       Date:  2021-02-25       Impact factor: 4.379

2.  Room-Temperature, Ionic-Liquid-Enhanced, Beta-Cyclodextrin-Based, Molecularly Imprinted Polymers for the Selective Extraction of Abamectin.

Authors:  Saqib Farooq; Bochang Chen; Shakeel Ahmad; Ihsan Muhammad; Quaid Hussain; Haiyan Wu
Journal:  Nanomaterials (Basel)       Date:  2022-03-20       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.