| Literature DB >> 27512279 |
Yeongyo Nam1, Ho Jun Lee2, Myongryol Choi2, Sangmi Chung3, Junhyung Park4, Jaeho Yu5.
Abstract
[Purpose] The purpose of this study was to investigate the effect of co-stabilizer muscle activation on knee joint position sense.Entities:
Keywords: Co-stabilizer muscle; Knee joint position sense; Sitting position
Year: 2016 PMID: 27512279 PMCID: PMC4968520 DOI: 10.1589/jpts.28.2119
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Fig. 1.Acumar™ digital inclinometer (model ACU360), Lafayette Instrument Company, Lafayette, IN, USA
Fig. 2.Placement of the digital inclinometer
Means and standard deviations of joint position matching error in slump and erect sitting at each target angle (Unit °)
| Sitting type | Target angle | Matching Error |
|---|---|---|
| Slump | 30° | 4.50 ± 3.08 |
| 45° | 3.83 ± 1.47 | |
| 80° | 2.67 ± 2.16 | |
| Erect | 30° | 3.50 ± 2.59 |
| 45° | 1.00 ± 0.63 | |
| 80° | 1.50 ± 1.38 |
Means and standard deviations of the difference between slump and erect sitting of joint position matching error at each target angle (Unit °)
| Target angle | Differences |
|---|---|
| Slump30°- Erect30° | 1.00 ± 2.10 |
| Slump45°- Erect45° | 2.67 ± 2.25* |
| Slump80°- Erect80° | 1.17 ± 2.92 |
*p<0.05