Literature DB >> 27508935

Objective assessment of compliance with intra- and extraoral removable appliances.

Angela Arreghini, Silvia Trigila, Luca Lombardo, Giuseppe Siciliani.   

Abstract

OBJECTIVE: To conduct an objective assessment of the level of compliance in young patients prescribed various types of removable appliances and to determine the influence of device type, treatment duration, and patient age, gender, psychological maturity, and awareness of monitoring on compliance.
MATERIALS AND METHODS: A total of 30 patients were fitted with either a class 2 (Frankel or bionator) or a class 3 (face mask) removable appliance, each bearing a compliance indicator chip, and they were instructed to wear them for 13 hours per day. Compliance was monitored by means of the sensor for an average of 8 months. Of the patients, 14 were informed that their appliance was fitted with a monitoring sensor, and 16 were not. The psychological maturity of all patients was assessed on the Nowicki-Strickland Locus of Control Scale, and the effect on compliance of this score as well as the patient- and treatment-related variables considered were determined via statistical analysis
Results: The mean compliance recorded by the chips was 8.6 ± 2.9 hours, far lower than the 13 hours prescribed, and younger patients showed significantly greater compliance than adolescents (P < .01). However, no significant differences in compliance were found between intra- and extraoral appliances, and neither gender, psychological scores, treatment duration, nor awareness of being monitored had any significant effect.
CONCLUSIONS: Compliance is generally very poor in young patients, regardless of their gender and psychological maturity. Although awareness of monitoring does not appear to boost compliance, such systems may be a valuable means of providing a dentist with objective information regarding their patients' compliance.

Entities:  

Keywords:  Compliance; Compliance indicator; Removable appliance; TheraMon system

Mesh:

Year:  2016        PMID: 27508935     DOI: 10.2319/020616-104.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  10 in total

1.  Class II treatment by palatal miniscrew-system appliance: A case report.

Authors:  Luca Lombardo; Giulia Occhiuto; Emanuele Paoletto; Bortolo Giuliano Maino; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2019-03-12       Impact factor: 2.079

2.  Class II subdivision with skeletal transverse maxillary deficit treated by single-sitting bone-borne appliance.

Authors:  Luca Lombardo; Mario Palone; Giuliano Maino; Emanuele Paoletto; Antonella Carlucci; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2021-01-01       Impact factor: 2.079

3.  Smartphone-based application for EMA assessment of awake bruxism: compliance evaluation in a sample of healthy young adults.

Authors:  Anna Colonna; Luca Lombardo; Giuseppe Siciliani; Alessandro Bracci; Luca Guarda-Nardini; Goran Djukic; Daniele Manfredini
Journal:  Clin Oral Investig       Date:  2019-10-24       Impact factor: 3.573

4.  3D Printed Customized Facemask for Maxillary Protraction in the Early Treatment of a Class III Malocclusion: Proof-of-Concept Clinical Case.

Authors:  Lorenzo Franchi; Alessandro Vichi; Patrizia Marti; Flavio Lampus; Simone Guercio; Annamaria Recupero; Veronica Giuntini; Cecilia Goracci
Journal:  Materials (Basel)       Date:  2022-05-24       Impact factor: 3.748

5.  How patient-selected colors for removable appliances are reflected in electronically tracked compliance (wear times and wear behavior).

Authors:  Timm C Schott; Dieter Menne
Journal:  Angle Orthod       Date:  2018-03-27       Impact factor: 2.079

6.  A methodology for evaluating tooth wear monitoring using timed automata modelling.

Authors:  Peter Wetselaar; Frank Lobbezoo; Pepijn de Jong; Umarah Choudry; Jasper van Rooijen; Rom Langerak
Journal:  J Oral Rehabil       Date:  2019-12-05       Impact factor: 3.837

7.  The application of a new clear removable appliance with an occlusal splint in early anterior crossbite.

Authors:  Jiayu Zhang; Yuzhi Yang; Xue Han; Tingting Lan; Fei Bi; Xiangchen Qiao; Weihua Guo
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

8.  Orthodontic Compliance Assessment: A Systematic Review.

Authors:  Marek Nahajowski; Joanna Lis; Michał Sarul
Journal:  Int Dent J       Date:  2022-08-10       Impact factor: 2.607

9.  Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study.

Authors:  Myungsoon Park; Yonghyun Na; Minbong Park; Janghoon Ahn
Journal:  Korean J Orthod       Date:  2017-07-27       Impact factor: 1.372

Review 10.  The Efficacy of a New AMCOP® Elastodontic Protocol for Orthodontic Interceptive Treatment: A Case Series and Literature Overview.

Authors:  Alessio Danilo Inchingolo; Assunta Patano; Giovanni Coloccia; Sabino Ceci; Angelo Michele Inchingolo; Grazia Marinelli; Giuseppina Malcangi; Valentina Montenegro; Claudia Laudadio; Chiara Di Pede; Mariagrazia Garibaldi; Zamira Kruti; Maria Elena Maggiore; Antonio Mancini; Ludovica Nucci; Ioana Roxana Bordea; Antonio Scarano; Felice Lorusso; Gianna Dipalma; Daniela Di Venere; Filippo Cardarelli; Francesco Inchingolo
Journal:  Int J Environ Res Public Health       Date:  2022-01-16       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.