A novel 384-multiwell microelectrode array for the impedimetric monitoring of Tau protein induced neurodegenerative processes.

Heinz-Georg Jahnke1, Dana Krinke1, Diana Seidel1, Katharina Lilienthal2, Sabine Schmidt1, Ronny Azendorf1, Michael Fischer2, Till Mack3, Frank Striggow3, Holger Althaus4, Andreas Schober2, Andrea A Robitzki5.   

Abstract

Over the last decades, countless bioelectronic monitoring systems were developed for the analysis of cells as well as complex tissues. Most studies addressed the sensitivity and specificity of the bioelectronic detection method in comparison to classical molecular biological assays. In contrast, the up scaling as a prerequisite for the practical application of these novel bioelectronic monitoring systems is mostly only discussed theoretically. In this context, we developed a novel 384-multiwell microelectrode array (MMEA) based measurement system for the sensitive label-free real-time monitoring of neurodegenerative processes by impedance spectroscopy. With respect to the needs of productive screening systems for robust and reproducible measurements on high numbers of plates, we focused on reducing the critical contacting of more than 400 electrodes for a 384-MMEA. Therefore, we introduced an on top array of immersive counter electrodes that are individually addressed by a multiplexer and connected all measurement electrodes on the 384-MMEA to a single contact point. More strikingly, our novel approach provided a comparable signal stability and sensitivity similar to an array with integrated counter electrodes. Next, we optimized a SH-SY5Y cell based tauopathy model by introducing a novel 5-fold Tau mutation eliminating the need of artificial tauopathy induction. In combination with our novel 384-MMEA based measurement system, the concentration and time dependent neuroregenerative effect of the kinase inhibitor SRN-003-556 could be quantitatively monitored. Thus, our novel screening system could be a useful tool to identify and develop potential novel therapeutics in the field of Tau-related neurodegenerative diseases.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  384-multiwell microelectrode array; Cell-based tauopathy model; Impedance spectroscopy; Kinase inhibitor SRN-003-556; Phenotypic screening; SH-SY5Y cells

Mesh:

Substances:

Year:  2016        PMID: 27506337     DOI: 10.1016/j.bios.2016.07.074

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Impedance-based cellular assays for regenerative medicine.

Authors:  W Gamal; H Wu; I Underwood; J Jia; S Smith; P O Bagnaninchi
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2018-07-05       Impact factor: 6.237

Review 2.  Label-Free Physical Techniques and Methodologies for Proteins Detection in Microfluidic Biosensor Structures.

Authors:  Georgii Konoplev; Darina Agafonova; Liubov Bakhchova; Nikolay Mukhin; Marharyta Kurachkina; Marc-Peter Schmidt; Nikolay Verlov; Alexander Sidorov; Aleksandr Oseev; Oksana Stepanova; Andrey Kozyrev; Alexander Dmitriev; Soeren Hirsch
Journal:  Biomedicines       Date:  2022-01-18

Review 3.  Recent Advances in Monitoring Cell Behavior Using Cell-Based Impedance Spectroscopy.

Authors:  Qusai Hassan; Soha Ahmadi; Kagan Kerman
Journal:  Micromachines (Basel)       Date:  2020-06-13       Impact factor: 2.891

4.  Proliferation and Cluster Analysis of Neurons and Glial Cell Organization on Nanocolumnar TiN Sub-Strates.

Authors:  Alice Abend; Chelsie Steele; Sabine Schmidt; Ronny Frank; Heinz-Georg Jahnke; Mareike Zink
Journal:  Int J Mol Sci       Date:  2020-08-28       Impact factor: 5.923