Literature DB >> 27501900

Value of ultra-low-dose chest CT with iterative reconstruction for selected emergency room patients with acute dyspnea.

Francesco Macri1, Joel Greffier2, Fabricio Pereira2, Alina Chica Rosa2, Elina Khasanova2, Pierre-Geraut Claret3, Ahmed Larbi2, Gianfranco Gualdi4, Jean Paul Beregi2.   

Abstract

OBJECTIVE: To compare the diagnostic confidence between low-dose computed-tomography (LDCT) and ultra-low-dose CT (ULDCT) of the chest on a single source CT system (SSCT) for patients with acute dyspnoea.
MATERIALS AND METHODS: One hundred thirty-three consecutive dyspnoeic patients referred from the emergency room (ER) were selected to undergo two sequential non-enhanced chest CT acquisitions: LDCT first acquisition (100kVp and 60mAs), followed by ULDCT (100kVp±20 and 10mAs). Images were reconstructed with sinogram affirmed reconstruction (SAFIRE). Objective and subjective image quality assessments were made. Two radiologists evaluated subjective image quality and the level of diagnostic confidence as certain or uncertain.
RESULTS: The mean effective doses (ED) were 1.164±0.403 and 0.182±0.028mSv for LDCT and ULDCT, respectively. Objective image quality improved significantly on lung images of ULDCT compared with LDCT (p<0.05). Subjective image quality was rated excellent/good in 90% of patients with BMI=25kg/m(2) for ULDCT. The level of diagnostic confidence was "certain" in all cases for both radiologists with excellent inter-observer agreement (k=1).
CONCLUSION: Chest ULDCT with SAFIRE on a SSCT allows a high level diagnostic confidence for the evaluation of selected acute dyspnoeic patients.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Chest computed tomography; Emergency room; Iterative; Radiation protection; Reconstruction; Ultra-low-dose

Mesh:

Year:  2016        PMID: 27501900     DOI: 10.1016/j.ejrad.2016.06.024

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Submillisievert chest dual energy computed tomography: a pilot study.

Authors:  Rodrigo Canellas; Jeanne B Ackman; Subba R Digumarthy; Melissa Price; Alexi Otrakji; Shaunagh McDermott; Amita Sharma; Mannudeep K Kalra
Journal:  Br J Radiol       Date:  2017-12-05       Impact factor: 3.039

2.  Radiation protection: Factors influencing compliance to referral guidelines in minor chest trauma.

Authors:  Denis Tack; Fabian Louagé; Alain Van Muylem; Nigel Howarth; Pierre Alain Gevenois
Journal:  Eur Radiol       Date:  2017-10-27       Impact factor: 5.315

3.  CT iterative reconstruction algorithms: a task-based image quality assessment.

Authors:  J Greffier; J Frandon; A Larbi; J P Beregi; F Pereira
Journal:  Eur Radiol       Date:  2019-07-29       Impact factor: 5.315

4.  Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.

Authors:  Aymeric Hamard; Joel Greffier; Sophie Bastide; Ahmed Larbi; Takieddine Addala; Alexandre Sadate; Jean-Paul Beregi; Julien Frandon
Journal:  Eur Radiol       Date:  2020-10-09       Impact factor: 5.315

5.  Comparison of acquisition and iterative reconstruction parameters in abdominal computed tomography-guided procedures: a phantom study.

Authors:  Julien Frandon; Philippe Akessoul; Aymeric Hamard; Edinaud Bezandry; Romaric Loffroy; Takieddine Addala; Martin M Bertrand; Jean-Paul Beregi; Joël Greffier
Journal:  Quant Imaging Med Surg       Date:  2022-01

6.  Ultra-low-dose chest CT performance for the detection of viral pneumonia patterns during the COVID-19 outbreak period: a monocentric experience.

Authors:  Joël Greffier; Adel Hoballah; Alexandre Sadate; Fabien de Oliveira; Pierre-Geraud Claret; Hélène de Forges; Paul Loubet; Jean-Marc Mauboussin; Aymeric Hamard; Jean-Paul Beregi; Julien Frandon
Journal:  Quant Imaging Med Surg       Date:  2021-07

7.  CARE Dose 4D combined with sinogram-affirmed iterative reconstruction improved the image quality and reduced the radiation dose in low dose CT of the small intestine.

Authors:  Lin Wang; Shenchu Gong; Jushun Yang; Jie Zhou; Jing Xiao; Jin-Hua Gu; Hong Yang; Jianfeng Zhu; Bosheng He
Journal:  J Appl Clin Med Phys       Date:  2018-12-03       Impact factor: 2.102

8.  OPTimal IMAging strategy in patients suspected of non-traumatic pulmonary disease at the emergency department: chest X-ray or ultra-low-dose CT (OPTIMACT)-a randomised controlled trial chest X-ray or ultra-low-dose CT at the ED: design and rationale.

Authors:  Inge A H van den Berk; Maadrika M N P Kanglie; Tjitske S R van Engelen; Shandra Bipat; Marcel G W Dijkgraaf; Patrick M M Bossuyt; Wouter de Monyé; Jan M Prins; Jaap Stoker
Journal:  Diagn Progn Res       Date:  2018-08-08

9.  OPTimal IMAging strategy in patients suspected of non-traumatic pulmonary disease at the emergency department: chest X-ray or ultra-low-dose chest CT (OPTIMACT) trial-statistical analysis plan.

Authors:  Maadrika M N P Kanglie; Shandra Bipat; Inge A H van den Berk; Tjitske S R van Engelen; Marcel G W Dijkgraaf; Jan M Prins; Jaap Stoker; Patrick M M Bossuyt
Journal:  Trials       Date:  2020-05-14       Impact factor: 2.279

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.