Literature DB >> 27499270

Impaired renal function is associated with recurrence after cryoballoon catheter ablation for paroxysmal atrial fibrillation: A potential effect of non-pulmonary vein foci.

Satoshi Yanagisawa1, Yasuya Inden2, Hiroyuki Kato3, Aya Fujii3, Yoshiaki Mizutani3, Tadahiro Ito3, Yosuke Kamikubo3, Yasunori Kanzaki3, Monami Ando3, Makoto Hirai4, Rei Shibata1, Toyoaki Murohara3.   

Abstract

BACKGROUND: Atrial fibrillation (AF) and chronic kidney disease (CKD) are closely related. The present study aimed to evaluate the association between estimated glomerular filtration rate (eGFR) and outcomes after cryoballoon catheter ablation for AF.
METHODS: We included a total of 110 patients (64.0±10.1 years, 64% men) with paroxysmal AF who underwent second-generation cryoballoon catheter ablation in this study. Recurrence and change in renal function after ablation were assessed by stratification of eGFR sub-groups.
RESULTS: During a mean follow-up period of 9 months, 20 (18%) patients had AF recurrence after the first catheter ablation procedure. Multivariate Cox regression analysis showed that eGFR [hazard ratio (HR) 0.97, 95% confidence interval (CI) 0.93-0.99, p=0.047], non-pulmonary vein (PV) ectopic beats at initial ablation (HR 2.92, 95% CI 1.03-8.27, p=0.043), and history of stroke (HR 7.47, 95% CI 2.30-24.2, p=0.001) were independent predictors of recurrence after the ablation. Among the CKD groups, recurrence was found in 7% (1/15), 12% (9/73), and 46% (10/22) of the eGFR ≥90mL/min/1.73m2, eGFR 60-89.9mL/min/1.73m2, and eGFR 30-59.9mL/min/1.73m2 groups, respectively (p=0.001). Kaplan-Meier survival curves demonstrated that patients with eGFR 30-59.9mL/min/1.73m2 had significantly worse prognosis than did the other groups (log-rank p<0.001). In addition, non-PV ectopic beats at initial ablation were detected in 7% (1/15), 14% (10/73), and 50% (11/22) of the patients among the three CKD groups, respectively (p<0.001). No patients developed contrast-induced nephropathy after the catheter ablation procedure.
CONCLUSIONS: Low eGFR at baseline was an independent predictor of recurrence after cryoballoon ablation for paroxysmal AF. The presence of non-PV ectopic beats was significantly increased in patients with impaired renal function, which might be associated with a poor outcome.
Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Contrast-induced nephropathy; Cryoballoon catheter ablation; Estimated glomerular filtration rate; Non-pulmonary vein foci

Mesh:

Year:  2016        PMID: 27499270     DOI: 10.1016/j.jjcc.2016.07.008

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  7 in total

1.  Elevated Plasma Vitamin B12 Concentrations Are Independent Predictors of In-Hospital Mortality in Adult Patients at Nutritional Risk.

Authors:  Silvia Cappello; Emanuele Cereda; Mariangela Rondanelli; Catherine Klersy; Barbara Cameletti; Riccardo Albertini; Daniela Magno; Marilisa Caraccia; Annalisa Turri; Riccardo Caccialanza
Journal:  Nutrients       Date:  2016-12-23       Impact factor: 5.717

2.  Chronic kidney disease and arrhythmias: conclusions from a Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference.

Authors:  Mintu P Turakhia; Peter J Blankestijn; Juan-Jesus Carrero; Catherine M Clase; Rajat Deo; Charles A Herzog; Scott E Kasner; Rod S Passman; Roberto Pecoits-Filho; Holger Reinecke; Gautam R Shroff; Wojciech Zareba; Michael Cheung; David C Wheeler; Wolfgang C Winkelmayer; Christoph Wanner
Journal:  Eur Heart J       Date:  2018-06-21       Impact factor: 29.983

3.  Indoxyl Sulphate is Associated with Atrial Fibrillation Recurrence after Catheter Ablation.

Authors:  Fumi Yamagami; Kazuko Tajiri; Kosuke Doki; Masayuki Hattori; Junya Honda; Satoshi Aita; Tomohiko Harunari; Hiro Yamasaki; Nobuyuki Murakoshi; Yukio Sekiguchi; Masato Homma; Naohiko Takahashi; Kazutaka Aonuma; Akihiko Nogami; Masaki Ieda
Journal:  Sci Rep       Date:  2018-11-22       Impact factor: 4.379

Review 4.  Uremic Toxins and Atrial Fibrillation: Mechanisms and Therapeutic Implications.

Authors:  Fumi Yamagami; Kazuko Tajiri; Dai Yumino; Masaki Ieda
Journal:  Toxins (Basel)       Date:  2019-10-13       Impact factor: 4.546

5.  Pharmacological Cardioversion in Patients with Recent-Onset Atrial Fibrillation and Chronic Kidney Disease Subanalysis of the CANT II Study.

Authors:  Beata Ceynowa-Sielawko; Maciej T Wybraniec; Aleksandra Topp-Zielińska; Aleksander Maciąg; Dawid Miśkowiec; Paweł Balsam; Maciej Wójcik; Wojciech Wróbel; Michał M Farkowski; Edyta Ćwiek-Rębowska; Krzysztof Ozierański; Robert Błaszczyk; Karolina Bula; Tomasz Dembowski; Michał Peller; Bartosz Krzowski; Wojciech Wańha; Marek Koziński; Jarosław D Kasprzak; Hanna Szwed; Katarzyna Mizia-Stec; Marek Szołkiewicz
Journal:  Int J Environ Res Public Health       Date:  2022-04-17       Impact factor: 3.390

6.  An intriguing relation between atrial fibrillation and contrast-induced nephropathy.

Authors:  Kumar Ashish; Dhrubajyoti Bandyopadhyay; Raktim K Ghosh; Jian Liang Tan; Subhasish Bose
Journal:  Int J Cardiol Heart Vasc       Date:  2018-10-24

7.  Value of cystatin C in predicting atrial fibrillation recurrence after radiofrequency catheter ablation.

Authors:  Li-Li Jin; Ling You; Rui-Qin Xie
Journal:  J Geriatr Cardiol       Date:  2018-12       Impact factor: 3.327

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.