| Literature DB >> 27497775 |
Ali Karimi1, Samira Eslamizad2, Maryam Mostafaee3, Zahra Momeni4, Fateme Ziafati4, Shokoofe Mohammadi4.
Abstract
BACKGROUND: According to the growth of photocopier usage in workplaces, the potential risk of occupational exposure to the airborne chemicals has been raised up. Hence, monitoring the photocopy worker's respiratory functions seems to be necessary. We aimed to evaluate the respiratory health on photocopy and printing workers so that a reliable description can be made about their occupational hygiene.Entities:
Keywords: Photocopy and Printing Workers; Pulmonary Function Indexes; Respiratory Symptom
Mesh:
Substances:
Year: 2016 PMID: 27497775 PMCID: PMC7189934
Source DB: PubMed Journal: J Res Health Sci ISSN: 2228-7795
Demographic information of photocopy workers and the unexposed group
|
|
|
|
| ||
|
|
|
|
|
| |
| Age (yr) | 34.32 | 05.71 | 33.42 | 08.40 | 0.951 |
| BMI | 69.61 | 12.72 | 69.35 | 14.30 | 0.836 |
| Work experience (yr) | 08.93 | 05.64 | 12.01 | 07.47 | 0.001 |
|
|
|
|
|
|
|
| Smoking status | 0.001 | ||||
| Smoker | 006 | 04.4 | 035 | 23.3 | |
| Nonsmoker | 108 | 95.6 | 115 | 76.7 | |
Comparing respiratory functions of photocopy workers and the unexposed group
|
|
|
|
| ||
|
|
|
|
| ||
| Vital Capacity(VC)% | 85.64 | 9.21 | 83.21 | 11.51 | 0.065 |
| Forced Vital Capacity(FVC) % | 90.52 | 9.30 | 86.93 | 12.53 | 0.008 |
| Forced expiratory volume in 1 second (FEV1) % | 91.13 | 9.62 | 87.04 | 12.80 | 0.003 |
| FEV1/FVC% | 84.78 | 4.63 | 84.97 | 07.24 | 0.790 |
Adjusted and unadjusted OR (odds ratio) of respiratory symptoms of photocopy workers in comparison with unexposed group, on the basis of multiple logistic
|
|
|
|
|
|
|
|
| Cough | ||||||
| Absent | 100 | 112 | 1.00 | 1.00 | ||
| Present | 14 | 38 | 2.33 (1.19, 2.55) | 0.012 | 2.61 (1.21, 5.62) | 0.016 |
| Sputum | ||||||
| Absent | 103 | 120 | 1.00 | 1.00 | ||
| Present | 11 | 30 | 1.52 (0.72, 3.23) | 0.181 | 1.31 (0.93, 1.03) |
0.74 |
| Phlegmatic cough | ||||||
| Absent | 101 | 119 | 1.00 | 1.00 | ||
| Present | 13 | 31 | 1.92 (0.95, 3.84) | 0.069 | 2.05 (0.92, 4.63) | 0.079 |
| Wheezing | ||||||
| Absent | 111 | 133 | 1.00 | 1.00 | ||
| Present | 3 | 17 | 4.18 (1.19, 14.6) | 0.016 | 2.92 (1.25, 6.84) | 0.013 |
| Shortness of breath | ||||||
| Absent | 93 | 120 | 1.00 | 1.00 | ||
| Present | 21 | 30 | 0.73 (0.38, 1.37) | 0.321 | 1.32 (0.74, 2.36) | 0.342 |
| Press on chest | ||||||
| Absent | 97 | 120 | 1.00 | 1.00 | ||
| Present | 17 | 30 | 1.40 (0.73, 2.68) | 0.204 | 1.27 (0.60, 2.67) | 0.520 |
a adjusted for age, work experience, smoking, BMI and marital status