Electrochemical DNA probe for Hg(2+) detection based on a triple-helix DNA and Multistage Signal Amplification Strategy.

Huan Wang1, Yihe Zhang2, Hongmin Ma3, Xiang Ren3, Yaoguang Wang3, Yong Zhang3, Qin Wei4.   

Abstract

In this work, an ultrasensitive electrochemical sensor was developed for detection of Hg(2+). Gold nanoparticles decorated bovine serum albumin reduction of graphene oxide (AuNP-BSA-rGO) were used as subsurface material for the immobilization of triple-helix DNA. The triple-helix DNA containing a thiol labelled single-stranded DNA (sDNA) and a thymine-rich DNA (T-rich DNA), which could be unwinded in the present of Hg(2+) to form more stable thymine-Hg(2+)-thymine (T-Hg(2+)-T) complex. T-Hg(2+)-T complex was then removed and the sDNA was left on the electrode. At this time, gold nanoparticle carrying thiol labelled cytosine-rich complementary DNA (cDNA-AuNP) could bind with the free sDNA. Meanwhile, the other free cDNA on AuNP could bind with each other in the present of Ag(+) to form the stable cytosine-Ag(+)-cytosine (C-Ag(+)-C) complex and circle amplification. Plenty of C-Ag(+)-C could form silver nanoclusters by electrochemical reduction and the striping signal of Ag could be measured for purpose of the final electrochemical detection of Hg(2+). This sensor could detect Hg(2+) over a wide concentration range from 0.1 to 130nM with a detection limit of 0.03nM.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cytosine–Ag(+)–cytosine complex; Hg(2+) detection; Multistage Signal Amplification Strategy; Thymine–Hg(2+)–thymine complex; Triple-helix DNA

Mesh:

Substances:

Year:  2016        PMID: 27497197     DOI: 10.1016/j.bios.2016.07.098

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A voltammetric biosensor for mercury(II) using reduced graphene oxide@gold nanorods and thymine-Hg(II)-thymine interaction.

Authors:  Huali Jin; Mingli Zhang; Min Wei; Jun-Hu Cheng
Journal:  Mikrochim Acta       Date:  2019-03-30       Impact factor: 5.833

2.  A Facile Aptasensor for Instantaneous Determination of Cadmium Ions Based on Fluorescence Amplification Effect of MOPS on FAM-Labeled Aptamer.

Authors:  Yang Liu; Dongwei Zhang; Jina Ding; Kashif Hayat; Xijia Yang; Xuejia Zhan; Dan Zhang; Yitong Lu; Pei Zhou
Journal:  Biosensors (Basel)       Date:  2021-04-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.