Hassan Karimi-Maleh1, Abdollah Fallah Shojaei2, Khalil Tabatabaeian3, Fatemeh Karimi4, Shahryar Shakeri5, Reza Moradi6.
Abstract
6-Mercaptopurine, 6-thioguanine and dasatinib are three important anticancer drugs with high adverse effects in human body. In this study, a Pt/MWCNTs-1-butyl-3-methylimidazolium hexafluoro phosphate-modified carbon paste electrode was developed for the simultaneously determination of 6-mercaptopurine, 6-thioguanine and dasatinib for the first time. The Pt/MWCNTs synthesized by polyol method and have been characterized by transmission electron microscopy and X-ray diffraction methods. The obtained data revealed that the electro-oxidation of 6-mercaptopurine, 6-thioguanine and dasatinib is facilitated as a novel voltammetric sensor. After optimization of electrochemical parameters employing this sensor at pH 8.0, the oxidation peak currents for 6-mercaptopurine, 6-thioguanine and dasatinib were found to vary linearly with their concentrations in the range of 0.05-550μM; 0.1-500μM and 5.0-500μM with detection limits of 0.009μM, 0.05μM and 1.0μM respectively using square wave voltammetric method. The modified electrode has been applied for the selective and precise analysis of 6-mercaptopurine, 6-thioguanine and dasatinib in pharmaceutical formulations and urine samples.Entities:
Keywords: 6-Mercaptopurine; 6-Thioguanine; Dasatinib; Ionic liquid; Pt/MWCNTs; Sensor
Mesh:
Substances:
Year: 2016 PMID: 27494812 DOI: 10.1016/j.bios.2016.07.086
Source DB: PubMed Journal: Biosens Bioelectron ISSN: 0956-5663 Impact factor: 10.618