Literature DB >> 27490315

Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization.

Dong Zeng1, Yuanyuan Gao1, Jing Huang1, Zhaoying Bian1, Hua Zhang1, Lijun Lu1, Jianhua Ma2.   

Abstract

Multienergy computed tomography (MECT) allows identifying and differentiating different materials through simultaneous capture of multiple sets of energy-selective data belonging to specific energy windows. However, because sufficient photon counts are not available in each energy window compared with that in the whole energy window, the MECT images reconstructed by the analytical approach often suffer from poor signal-to-noise and strong streak artifacts. To address the particular challenge, this work presents a penalized weighted least-squares (PWLS) scheme by incorporating the new concept of structure tensor total variation (STV) regularization, which is henceforth referred to as 'PWLS-STV' for simplicity. Specifically, the STV regularization is derived by penalizing higher-order derivatives of the desired MECT images. Thus it could provide more robust measures of image variation, which can eliminate the patchy artifacts often observed in total variation (TV) regularization. Subsequently, an alternating optimization algorithm was adopted to minimize the objective function. Extensive experiments with a digital XCAT phantom and meat specimen clearly demonstrate that the present PWLS-STV algorithm can achieve more gains than the existing TV-based algorithms and the conventional filtered backpeojection (FBP) algorithm in terms of both quantitative and visual quality evaluations.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Keywords:  Multienergy computed tomography; Penalized weighted least-squares; Regularization; Structure tensor total variation

Mesh:

Year:  2016        PMID: 27490315     DOI: 10.1016/j.compmedimag.2016.07.002

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  11 in total

Review 1.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

2.  Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

Authors:  Houjin Zhang; Dong Zeng; Jiahui Lin; Hao Zhang; Zhaoying Bian; Jing Huang; Yuanyuan Gao; Shanli Zhang; Hua Zhang; Qianjin Feng; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2017-05-04       Impact factor: 3.609

3.  A Robust Regularizer for Multiphase CT.

Authors:  Jingyan Xu; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2020-01-24       Impact factor: 10.048

4.  Multi-energy CT reconstruction using tensor nonlocal similarity and spatial sparsity regularization.

Authors:  Wenkun Zhang; Ningning Liang; Zhe Wang; Ailong Cai; Linyuan Wang; Chao Tang; Zhizhong Zheng; Lei Li; Bin Yan; Guoen Hu
Journal:  Quant Imaging Med Surg       Date:  2020-10

5.  Ultra-Low-Dose Spectral CT Based on a Multi-level Wavelet Convolutional Neural Network.

Authors:  Minjae Lee; Hyemi Kim; Hyo-Min Cho; Hee-Joung Kim
Journal:  J Digit Imaging       Date:  2021-09-29       Impact factor: 4.056

6.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

7.  Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction.

Authors:  Shanzhou Niu; Gaohang Yu; Jianhua Ma; Jing Wang
Journal:  Inverse Probl       Date:  2018-01-10       Impact factor: 2.407

8.  Non-Local Low-Rank Cube-Based Tensor Factorization for Spectral CT Reconstruction.

Authors:  Weiwen Wu; Fenglin Liu; Yanbo Zhang; Qian Wang; Hengyong Yu
Journal:  IEEE Trans Med Imaging       Date:  2018-10-26       Impact factor: 10.048

9.  Iterative reconstruction for photon-counting CT using prior image constrained total generalized variation.

Authors:  Shanzhou Niu; You Zhang; Yuncheng Zhong; Guoliang Liu; Shaohui Lu; Xile Zhang; Shengzhou Hu; Tinghua Wang; Gaohang Yu; Jing Wang
Journal:  Comput Biol Med       Date:  2018-10-22       Impact factor: 4.589

Review 10.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
View more