PURPOSE: To assess the efficacy outcomes of implanting intrastromal corneal ring segments (ICRS) to correct paracentral keratoconus.
METHODS: Four hundred nine eyes with paracentral keratoconus, in which the differences between the axes of refractive cylinder and the corneal flattest meridian and the comatic aberration map were less than 30 degrees, were evaluated before and after the implantation of Ferrara-type ICRS. Snellen uncorrected and best-corrected distance visual acuity, residual refractive errors analyzed with vector analysis, and the root mean square for corneal coma-like aberration for a pupil size of 4.5 mm were recorded before and 6 months after ICRS implantation.
RESULTS: The mean uncorrected distance visual acuity (Snellen decimal scale) rose from 0.19 ± 0.19 before ICRS implantation to 0.42 ± 0.30 after implantation (P < 0.0001). The mean preoperative best-corrected distance visual acuity was 0.69 ± 0.24 and the postoperative value was 0.77 ± 0.23 (P < 0.0001). The safety index was 1.13. The spherical equivalent declined steeply after ICRS implantation (P < 0.0001). Cylinder power decreased by more than 50% in 71% of the eyes. The root mean square for corneal coma-like aberration for a 4.5-mm pupil changed from 1.32 ± 1.01 μm before surgery to 1.06 ± 0.85 μm after surgery (P ≤ 0.001).
CONCLUSIONS: The Ferrara-type ICRS implantation is a safe and effective procedure for treating patients with keratoconus that meets the morphological characteristics of the sample under study.

Entities:  

Mesh:

Year:  2016        PMID: 27490048     DOI: 10.1097/ICO.0000000000000978

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  7 in total

Review 1.  Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality.

Authors:  L Fernández-Vega-Cueto; V Romano; R Zaldivar; C H Gordillo; F Aiello; D Madrid-Costa; J F Alfonso
Journal:  J Ophthalmol       Date:  2017-12-18       Impact factor: 1.909

2.  Clinical Outcomes of Sequential Intrastromal Corneal Ring Segments and an Extended Range of Vision Intraocular Lens Implantation in Patients with Keratoconus and Cataract.

Authors:  C Lisa; R Zaldivar; A Fernández-Vega Cueto; R M Sanchez-Avila; D Madrid-Costa; J F Alfonso
Journal:  J Ophthalmol       Date:  2018-04-19       Impact factor: 1.909

3.  Long-Term Follow-Up of Intrastromal Corneal Ring Segments in Paracentral Keratoconus with Coincident Corneal Keratometric, Comatic, and Refractive Axes: Stability of the Procedure.

Authors:  Luis Fernández-Vega Cueto; Carlos Lisa; David Madrid-Costa; Jesús Merayo-Lloves; José F Alfonso
Journal:  J Ophthalmol       Date:  2017-08-29       Impact factor: 1.909

Review 4.  Efficacy of Different Procedures of Intra-Corneal Ring Segment Implantation in Keratoconus: a Systematic Review and Meta-Analysis.

Authors:  Cédric Benoist d'Azy; Bruno Pereira; Frédéric Chiambaretta; Frédéric Dutheil
Journal:  Transl Vis Sci Technol       Date:  2019-06-11       Impact factor: 3.283

5.  Asymmetric Thickness Intracorneal Ring Segments for Keratoconus.

Authors:  Pedro Manuel Baptista; João Heitor Marques; Miguel Mesquita Neves; Miguel Gomes; Luís Oliveira
Journal:  Clin Ophthalmol       Date:  2020-12-16

6.  Evaluation of a Tangential Map-Based Nomogram for Intrastromal Corneal Ring Segments' Implantation in Keratoconus: One Year Results.

Authors:  Adel Galal Zaky; Mahmoud Tawfik KhalafAllah; Abdelrahman Elsebaey Sarhan; Moataz Faiz Elsawy
Journal:  J Ophthalmol       Date:  2020-02-19       Impact factor: 1.909

7.  Corneal Biomechanics After Intrastromal Ring Surgery: Optomechanical In Silico Assessment.

Authors:  Miguel Ángel Ariza-Gracia; Julio Flecha-Lescún; Philippe Büchler; Begoña Calvo
Journal:  Transl Vis Sci Technol       Date:  2020-10-21       Impact factor: 3.283

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.