Pre- and postoperative correlation of patient-reported outcome measures with standardized Timed Up and Go (TUG) test results in lumbar degenerative disc disease.

Oliver P Gautschi1,2, Holger Joswig3, Marco V Corniola4, Nicolas R Smoll5, Karl Schaller4, Gerhard Hildebrandt5, Martin N Stienen4,5.   

Abstract

BACKGROUND: The Timed Up and Go (TUG) test is a reliable tool for evaluating objective functional impairment (OFI) in patients with degenerative disc disease before a surgical intervention. The aim of this study is to assess the validity of the TUG test to measure change in function postoperatively.
METHODS: In a prospective two-center study, OFI was assessed by the TUG test in patients scheduled for lumbar spine surgery, as well as 3 days (D3) and 6 weeks (W6) postoperatively. At each time point, the TUG test results were correlated with established subjective measures of pain intensity (visual analogue scale (VAS) for back and leg pain), functional impairment (Oswestry Disability Index (ODI)) and health-related quality of life (HRQoL; Short Form-12 (SF12)).
RESULTS: The patient cohort comprised 136 patients with a mean age of 57.7 years; 76 were males, 54 had a microdiscectomy for lumbar disc herniation, 58 a decompression for a lumbar spinal stenosis, 24 had a surgical fusion procedure. The mean OFI t-score was 125.1 before surgery, and as patients improved on the subjective measures in the postoperative interval, the OFI t-score likewise decreased to 118.8 (D3) and 103.4 (W6). The Pearson correlation coefficient (PCC) between the OFI t-score and VAS leg pain was 0.187 preoperatively (p = 0.029) and 0.252 at W6 (p = 0.003). The PCC between OFI t-score and the ODI was 0.324 preoperatively (p < 0.001) and 0.413 at W6 (p < 0.001). The PCC between OFI t-score and physical HRQoL (SF12) was -0.091 preoperatively (p = 0.293) and -0.330 at W6 (p < 0.001).
CONCLUSIONS: The TUG test is sensitive to change, and reflects the postoperative functional outcome even more exact than preoperatively, as indicated by better correlation coefficients of the OFI t-score with subjective measures of pain intensity, functional impairment and HRQoL.

Entities:  

Keywords:  Correlation; Degenerative disc disease; Lumbar spine surgery; Objective functional impairment; Objective outcome measurement; Postoperative outcome; Timed Up and Go test

Mesh:

Year:  2016        PMID: 27488842     DOI: 10.1007/s00701-016-2899-9

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  9 in total

1.  Level of Evidence for Reliability, Validity, and Responsiveness of Physical Capacity Tasks Designed to Assess Functioning in Patients With Low Back Pain: A Systematic Review Using the COSMIN Standards.

Authors:  Max Jakobsson; Annelie Gutke; Lidwine B Mokkink; Rob Smeets; Mari Lundberg
Journal:  Phys Ther       Date:  2019-04-01

2.  Validation of a novel range of motion assessment tool for the cervical spine: the HALO© digital goniometer.

Authors:  Ashley R Wilson-Smith; Saimurooban Muralidaran; Monish Maharaj; Matthew H Pelletier; Peter Beshara; Prashanth Rao; Louise M Pearce; Tian Wang; Ralph J Mobbs; William R Walsh
Journal:  J Spine Surg       Date:  2022-03

3.  functional mobility tests for evaluation of functionalities in patients with adult spinal deformity.

Authors:  Hyung Rae Lee; Jiwon Park; Dae-Woong Ham; Byung-Taek Kwon; Seong Jun Go; Ho-Joong Kim
Journal:  BMC Musculoskelet Disord       Date:  2022-04-27       Impact factor: 2.562

4.  Can objective functional impairment in lumbar degenerative disease be reliably assessed at home using the five-repetition sit-to-stand test? A prospective study.

Authors:  Victor E Staartjes; Femke Beusekamp; Marc L Schröder
Journal:  Eur Spine J       Date:  2019-01-24       Impact factor: 3.134

5.  Association between the instrumented timed up and go test and cognitive function, fear of falling and quality of life in community dwelling people with dementia.

Authors:  Jonathan M Williams; Samuel R Nyman
Journal:  J Frailty Sarcopenia Falls       Date:  2018-12-01

6.  Subtask Segmentation of Timed Up and Go Test for Mobility Assessment of Perioperative Total Knee Arthroplasty.

Authors:  Chia-Yeh Hsieh; Hsiang-Yun Huang; Kai-Chun Liu; Kun-Hui Chen; Steen Jun-Ping Hsu; Chia-Tai Chan
Journal:  Sensors (Basel)       Date:  2020-11-05       Impact factor: 3.576

7.  Smartphone-based real-life activity data for physical performance outcome in comparison to conventional subjective and objective outcome measures after degenerative lumbar spine surgery.

Authors:  Stefanos Voglis; Michal Ziga; Anna M Zeitlberger; Marketa Sosnova; Oliver Bozinov; Luca Regli; David Bellut; Astrid Weyerbrock; Martin N Stienen; Nicolai Maldaner
Journal:  Brain Spine       Date:  2022-03-18

8.  Objective activity tracking in spine surgery: a prospective feasibility study with a low-cost consumer grade wearable accelerometer.

Authors:  Martin N Stienen; Paymon G Rezaii; Allen L Ho; Anand Veeravagu; Corinna C Zygourakis; Christy Tomkins-Lane; Jon Park; John K Ratliff; Atman M Desai
Journal:  Sci Rep       Date:  2020-03-18       Impact factor: 4.379

9.  SIZE study: study protocol of a multicentre, randomised controlled trial to compare the effectiveness of an interarcuair decompression versus extended decompression in patients with intermittent neurogenic claudication caused by lumbar spinal stenosis.

Authors:  Jamie Arjun Sharma; Pravesh S Gadjradj; Wilco C Peul; Maurits W van Tulder; Wouter A Moojen; Biswadjiet S Harhangi
Journal:  BMJ Open       Date:  2020-10-06       Impact factor: 2.692

  9 in total