Literature DB >> 27487892

A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis.

Daniel Andreasen1, Koen Van Leemput2, Jens M Edmund3.   

Abstract

PURPOSE: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T1-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level.
METHODS: The data consisted of CT and T1-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAEvox) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose-volume histogram (DVH) point deviations and γ-index analysis.
RESULTS: The patch-based approach had an average MAEvox of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute-force search, with an average prediction time of 20.8 min.
CONCLUSIONS: The authors showed that a patch-based method based on affine registrations and T1-weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline.

Entities:  

Mesh:

Year:  2016        PMID: 27487892     DOI: 10.1118/1.4958676

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  mDixon-Based Synthetic CT Generation for PET Attenuation Correction on Abdomen and Pelvis Jointly Using Transfer Fuzzy Clustering and Active Learning-Based Classification.

Authors:  Pengjiang Qian; Yangyang Chen; Jung-Wen Kuo; Yu-Dong Zhang; Yizhang Jiang; Kaifa Zhao; Rose Al Helo; Harry Friel; Atallah Baydoun; Feifei Zhou; Jin Uk Heo; Norbert Avril; Karin Herrmann; Rodney Ellis; Bryan Traughber; Robert S Jones; Shitong Wang; Kuan-Hao Su; Raymond F Muzic
Journal:  IEEE Trans Med Imaging       Date:  2019-08-16       Impact factor: 10.048

2.  Magnetic resonance imaging-based pseudo computed tomography using anatomic signature and joint dictionary learning.

Authors:  Yang Lei; Hui-Kuo Shu; Sibo Tian; Jiwoong Jason Jeong; Tian Liu; Hyunsuk Shim; Hui Mao; Tonghe Wang; Ashesh B Jani; Walter J Curran; Xiaofeng Yang
Journal:  J Med Imaging (Bellingham)       Date:  2018-08-24

3.  Dose evaluation of MRI-based synthetic CT generated using a machine learning method for prostate cancer radiotherapy.

Authors:  Ghazal Shafai-Erfani; Tonghe Wang; Yang Lei; Sibo Tian; Pretesh Patel; Ashesh B Jani; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Med Dosim       Date:  2019-02-01       Impact factor: 1.482

4.  Effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning.

Authors:  Keisuke Usui; Keisuke Sasai; Koichi Ogawa
Journal:  Radiol Phys Technol       Date:  2018-03-14

5.  MRI-based pseudo CT synthesis using anatomical signature and alternating random forest with iterative refinement model.

Authors:  Yang Lei; Jiwoong Jason Jeong; Tonghe Wang; Hui-Kuo Shu; Pretesh Patel; Sibo Tian; Tian Liu; Hyunsuk Shim; Hui Mao; Ashesh B Jani; Walter J Curran; Xiaofeng Yang
Journal:  J Med Imaging (Bellingham)       Date:  2018-12-05

6.  MRI-based synthetic CT generation using semantic random forest with iterative refinement.

Authors:  Yang Lei; Joseph Harms; Tonghe Wang; Sibo Tian; Jun Zhou; Hui-Kuo Shu; Jim Zhong; Hui Mao; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

7.  Patch-based generative adversarial neural network models for head and neck MR-only planning.

Authors:  Peter Klages; Ilyes Benslimane; Sadegh Riyahi; Jue Jiang; Margie Hunt; Joseph O Deasy; Harini Veeraraghavan; Neelam Tyagi
Journal:  Med Phys       Date:  2019-12-25       Impact factor: 4.071

Review 8.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

9.  Feasibility of synthetic computed tomography generated with an adversarial network for multi-sequence magnetic resonance-based brain radiotherapy.

Authors:  Yuhei Koike; Yuichi Akino; Iori Sumida; Hiroya Shiomi; Hirokazu Mizuno; Masashi Yagi; Fumiaki Isohashi; Yuji Seo; Osamu Suzuki; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2020-01-23       Impact factor: 2.724

10.  Dosimetric evaluation of synthetic CT generated with GANs for MRI-only proton therapy treatment planning of brain tumors.

Authors:  Samaneh Kazemifar; Ana M Barragán Montero; Kevin Souris; Sara T Rivas; Robert Timmerman; Yang K Park; Steve Jiang; Xavier Geets; Edmond Sterpin; Amir Owrangi
Journal:  J Appl Clin Med Phys       Date:  2020-03-26       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.