Reliability and validity of the WATSMART three-dimensional optoelectric motion analysis system.

J P Scholz1.   

Abstract

Reliability and validity of the WATSMART (Waterloo Spatial Motion Analysis Recording Technique) system was evaluated under static and dynamic conditions. In experiment 1, infrared light-emitting diodes (IREDs) were placed at the axis and along the arms of a clinical goniometer. Twelve angles in 5-degree increments were each recorded 10 times at each of three spatial locations. Reliability was assessed using intraclass correlation coefficients (ICCs) and analysis-of-variance procedures to determine within-trial variability. The ICCs for all spatial locations exceeded .99. The 95% confidence interval for each angle was less than 0.5 degree in all cases. Criterion-referenced instrument validity was assessed with regression analysis. Slopes of the regression of reconstructed angle on reference angle were close to unity for each spatial location. A systematic error, however, that increased as the goniometer was rotated 45 degrees away from the cameras was evident. In experiment 2, a robotic arm was fitted with four IREDs and made to repeat a defined movement trajectory 10 times at each of three spatial locations. The ICCs for portions of each trajectory ranged from .20 to .99. The results show that reliable and valid results can be obtained from this motion analysis system if adequate precautions are taken to reduce unwanted light reflections. Reliability and validity decreased somewhat as the object was rotated further away from the plane in which the cameras were mounted.

Mesh:

Year:  1989        PMID: 2748722     DOI: 10.1093/ptj/69.8.679

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  6 in total

1.  Kinematic and electromyographic analysis of elbow flexion during inertial exercise.

Authors:  J E Tracy; S Obuchi; B Johnson
Journal:  J Athl Train       Date:  1995-09       Impact factor: 2.860

2.  Order parameters for the neural organization of single, multijoint limb movement patterns.

Authors:  J A Kelso; J J Buchanan; S A Wallace
Journal:  Exp Brain Res       Date:  1991       Impact factor: 1.972

3.  Test-retest reliability and inter-tester reliability of kinematic data from a three-dimensional gait analysis system.

Authors:  Hitoshi Tsushima; Meg E Morris; Jennifer McGinley
Journal:  J Jpn Phys Ther Assoc       Date:  2003

4.  Assessment of anteroposterior instability of the knee during gait.

Authors:  S Obuchi; P D Andrew; G S Cummings; B F Johnson
Journal:  J Jpn Phys Ther Assoc       Date:  1999

5.  Observations of improvement of reaching in five subjects with left hemiparesis.

Authors:  C A Trombly
Journal:  J Neurol Neurosurg Psychiatry       Date:  1993-01       Impact factor: 10.154

6.  Evaluation of Sagittal Spine-Pelvis-Lower Limb Alignment in Elderly Women with Pelvic Retroversion while Standing and Walking Using a Three-Dimensional Musculoskeletal Model.

Authors:  Ken Sasaki; Michio Hongo; Naohisa Miyakoshi; Toshiki Matsunaga; Shin Yamada; Hiroaki Kijima; Yoichi Shimada
Journal:  Asian Spine J       Date:  2017-08-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.