Literature DB >> 27477224

Retention force of differently fabricated telescopic PEEK crowns with different tapers.

Veronika Stock1, Christina Wagner, Susanne Merk, Malgorzata Roos, Patrick R Schmidlin, Marlis Eichberger, Bogna Stawarczyk.   

Abstract

To assess the retention force between primary and secondary PEEK crowns made by different fabrication methods. Primary crowns with different tapers (0°, 1°, and 2°) were fabricated and secondary crowns that were either milled from breCam BioHPP blanks, pressed from pellets (BioHPP Pellet) or granules (BioHPP Granulat) were produced. Each specimen was measured 20 times in a pulloff-test and results were analyzed using 2-/1-way ANOVA and linear regression analyses (p<0.05). Within 0° tapered crowns milled secondary crowns showed lower retention forces compared to pressed pellet crowns. Crowns with a 1° taper, however, showed no impact of the fabrication method on retention force. At a 2° taper, granular pressed crowns displayed lower values than their milled counterparts. Within the milled group, a 0° taper showed lower retention values than the higher tapers, whereas in the pressed groups, no impact of taper angle on retention force was found.

Mesh:

Year:  2016        PMID: 27477224     DOI: 10.4012/dmj.2015-249

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Retention of different CAD/CAM endocrowns bonded to severely damaged endodontically treated teeth: An in vitro study.

Authors:  Yasmin Elashmawy; Moustafa Aboushelib; Waleed Elshahawy
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

2.  Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

Authors:  Yoshifumi Tada; Tohru Hayakawa; Yoshiki Nakamura
Journal:  Materials (Basel)       Date:  2017-08-09       Impact factor: 3.623

3.  Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Marlis Eichberger; Patrick R Schmidlin; Malgorzata Roos; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-11-08       Impact factor: 3.623

Review 4.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

5.  Stress distribution on different bar materials in implant-retained palatal obturator.

Authors:  Regina Furbino Villefort; João Paulo Mendes Tribst; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Borges; Nívia Castro Binda; Carlos Eduardo de Almeida Ferreira; Marco Antonio Bottino; Sandra Lúcia Ventorim von Zeidler
Journal:  PLoS One       Date:  2020-10-30       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.