Literature DB >> 27477053

Characteristics of Residual Atrial Posterior Wall and Roof-Dependent Atrial Tachycardias after Pulmonary Vein Isolation.

Akinori Matsumoto1, Koji Fukuzawa2, Kunihiko Kiuchi1, Hiroki Konishi1, Hirotoshi Ichibori1, Hiroshi Imada1, Kiyohiro Hyogo1, Jun Kurose1, Tomofumi Takaya1, Shumpei Mori1, Akihiro Yoshida1, Ken-Ichi Hirata1, Tatsuya Nishii3, Atsushi Kono3.   

Abstract

BACKGROUND: Roof-dependent atrial tachycardia (roof AT) sometimes occurs after pulmonary vein isolation (PVI) of atrial fibrillation (AF). This study aimed to investigate the relationship between the anatomy of the residual left atrial posterior wall and occurrence of roof AT.
METHODS: A total of 265 patients with AF who underwent PVI were enrolled. After the PVI, induced or recurrent roof AT was confirmed by an entrainment maneuver or activation mapping using a three-dimensional (3D) mapping system. To identify the predictors of roof AT, the minimum distance between both PVI lines (d-PVI) was measured by a 3D mapping system and the anatomical parameters, including the left atrial (LA) diameter, left atrial volume index (LAVi), and shape of the left atrial roof, were analyzed by 3D computed tomography.
RESULTS: Roof AT was documented in 11 (4.2%) of 265 patients. A multivariable analysis demonstrated that the d-PVI, Deep V shape of the LA roof, and LAVi were associated with roof AT occurrences (d-PVI: odds ratio: 0.72, confidence interval [CI]: 0.61-0.86, P < 0.001; Deep V shape: odds ratio: 0.19, CI: 0.04-0.82, P = 0.03; LAVi: odds ratio: 1.05, CI: 1.02-1.07, P = 0.001). A receiver-operating characteristic curve analysis yielded an optimal cut-off value of 15.5 mm and 55.7 mL/m2 for the d-PVI and LAVi, respectively.
CONCLUSION: The shorter d-PVI at the LA roof, greater LAVi, and Deep V shape were associated with the occurrence of a roof AT.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D mapping system; atrial fibrillation; minimum distance between both PVI lines; pulmonary vein isolation; roof-dependent atrial tachycardia

Mesh:

Year:  2016        PMID: 27477053     DOI: 10.1111/pace.12927

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  Comparison of Cryoballoon and Hybrid surgical Posterior Wall Isolation for Persistent Atrial Fibrillation to conventional ablation.

Authors:  Eric Nordsieck; Xin J Zhang; Pankaj Malhotra; Dali Fan; Nayereh G Pezeshkian; Uma N Srivatsa
Journal:  J Atr Fibrillation       Date:  2019-02-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.