Literature DB >> 27477024

Drug Coated Balloon Is Less Effective for Treatment of DES In-Stent Restenosis Both in Native Coronary Arteries and Saphenous Vein Grafts: Results From a Bicenter Registry.

Markus Resch1, Patrick Ostheim2, Dierk H Endemann2, Kurt Debl2, Stefan Buchner2, Christoph Birner2, Lars S Maier2, Sebastian Kerber3, Andreas Luchner2,4, Daniel P Griese3.   

Abstract

BACKGROUND: The paclitaxel drug coated balloon (DCB) is an established treatment for bare metal stent (BMS) in-stent restenosis (ISR) in native coronary arteries. The evidence of DCB-application for drug eluting stent (DES) ISR both in native coronaries and saphenous vein grafts (SVG) is limited. Aim of our study was to compare the differential efficacy of DCB for treatment of BMS- and DES-ISR in native coronary vessels and SVGs. METHODS AND
RESULTS: N = 135 DCB-treated patients with available follow up (FU) angiography were included in this retrospective study. Patients received treatment between April 2009 and March 2013 at 2 tertiary care hospitals in Germany. DCB was applied in BMS-ISR (n = 65; 48%) and DES-ISR (n = 70; 52%). DCB-treated lesions were located in native coronary arteries (n = 110; 81%; BMS-ISR: n = 58; 53%; DES-ISR: n = 52; 47%) and SVGs (n = 25; 19%; BMS-ISR: n = 7, 28%; DES-ISR: n = 18, 72%). Median FU was 12 months. Endpoints were binary restenosis and target lesion revascularization (TLR). Binary restenosis (29% vs. 57%; P < 0.01) and TLR (18% vs. 46%; P < 0.01) were significantly more frequent in DES-ISR versus BMS-ISR. In SVGs, TLR was required in 72% (DES-ISR) versus 14% (BMS-ISR); P = 0.02. In the Kaplan-Meier-analysis freedom from both endpoints was significantly decreased in the DES-lesions both in the total population (binary restenosis P < 0.01; TLR P < 0.01) and native coronaries (binary restenosis P = 0.02; TLR P = 0.04).
CONCLUSIONS: DCB treatment is less effective in DES-ISR than in BMS-ISR. The diminished efficacy of DCB treatment is even more pronounced in DES-ISR located within degenerated SVGs.
© 2016, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27477024     DOI: 10.1111/joic.12324

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  2 in total

1.  Clinical Outcomes of Drug-Eluting versus Bare-Metal In-Stent Restenosis after the Treatment of Drug-Eluting Stent or Drug-Eluting Balloon: A Systematic Review and Meta-Analysis.

Authors:  Yi-Xing Yang; Yin Liu; Chang-Ping Li; Peng-Ju Lu; Jiao Wang; Jing Gao
Journal:  J Interv Cardiol       Date:  2020-06-26       Impact factor: 2.279

2.  Long-term outcomes of percutaneous coronary interventions within coronary artery bypass grafts.

Authors:  Rafał Januszek; Zbigniew Siudak; Artur Dziewierz; Tomasz Rakowski; Dariusz Dudek; Stanisław Bartuś
Journal:  Arch Med Sci       Date:  2019-01-30       Impact factor: 3.318