Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

Steven M Jackson1, M Samuel Cheng2, A Russell Smith3, Morey J Kolber4.   

Abstract

Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hand held dynamometer; Intrarater reliability; Lower extremity muscle performance; Stabilization device

Mesh:

Year:  2016        PMID: 27476066     DOI: 10.1016/j.math.2016.07.010

Source DB:  PubMed          Journal:  Musculoskelet Sci Pract        ISSN: 2468-7812            Impact factor:   2.520


  20 in total

1.  Psychometric Properties of Lower Extremity Strength Measurements Recorded in Community Settings in Independent Living Older Adults.

Authors:  Bader A Alqahtani; Patrick J Sparto; Susan L Whitney; Susan L Greenspan; Subashan Perera; Jennifer S Brach
Journal:  Exp Aging Res       Date:  2019-04-24       Impact factor: 1.645

2.  Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population.

Authors:  Rabail Rani Soomro; Hossein Karimi; Syed Amir Gillani
Journal:  Pak J Med Sci       Date:  2022 May-Jun       Impact factor: 2.340

3.  Investigating the Test-Retest Reliability and Validity of Hand-Held Dynamometry for Measuring Knee Strength in Older Women with Knee Osteoarthritis.

Authors:  Jaclyn N Chopp-Hurley; Emily G Wiebenga; Anthony A Gatti; Monica R Maly
Journal:  Physiother Can       Date:  2019       Impact factor: 1.037

4.  Correlation between isometric strength in five muscle groups and inclination angles of spine.

Authors:  Zoran Šarčević; Dragan Savić; Andreja Tepavčević
Journal:  Eur Spine J       Date:  2019-10-29       Impact factor: 3.134

5.  THE INFLUENCE OF HIP JOINT ANGLE ON THE RATIO BETWEEN ADDUCTION AND ABDUCTION TORQUE IN EXPERIENCED, RECREATIONAL MALE ICE HOCKEY PLAYERS.

Authors:  Patrick Welsh; Scott Howitt; Samuel J Howarth
Journal:  Int J Sports Phys Ther       Date:  2020-02

6.  MEASURES OF HIP MUSCLE STRENGTH AND RATE OF FORCE DEVELOPMENT USING A FIXATED HANDHELD DYNAMOMETER: INTRA-TESTER INTRA-DAY RELIABILITY OF A CLINICAL SET-UP.

Authors:  Lasse Ishøi; Per Hölmich; Kristian Thorborg
Journal:  Int J Sports Phys Ther       Date:  2019-09

7.  LESS THAN HALF OF ACL-RECONSTRUCTED ATHLETES ARE CLEARED FOR RETURN TO PLAY BASED ON PRACTICE GUIDELINE CRITERIA: RESULTS FROM A PROSPECTIVE COHORT STUDY.

Authors:  van Melick N; Hoogeboom Tj; Pronk Y; Rutten B; van Tienen Tg; Nijhuis-van der Sanden Mwg; van Cingel Reh
Journal:  Int J Sports Phys Ther       Date:  2020-12

8.  Assessing the Reliability of Handheld Dynamometry and Ultrasonography to Measure Quadriceps Strength and Muscle Thickness in Children, Adolescents, and Young Adults.

Authors:  Kelly Rock; Christa Nelson; Odessa Addison; Victoria Marchese
Journal:  Phys Occup Ther Pediatr       Date:  2021-02-09       Impact factor: 2.297

9.  Clinimetric properties of hip abduction strength measurements obtained using a handheld dynamometer in individuals with a lower extremity amputation.

Authors:  Ruud A Leijendekkers; Gerben van Hinte; Amy D Sman; J Bart Staal; Maria W G Nijhuis-van der Sanden; Thomas J Hoogeboom
Journal:  PLoS One       Date:  2017-06-22       Impact factor: 3.240

10.  Comparison of gluteus medius strength between individuals with obesity and normal-weight individuals: a cross-sectional study.

Authors:  Rafael Ratti Fenato; Allan Cezar Faria Araujo; Ana Tereza Bittencourt Guimarães
Journal:  BMC Musculoskelet Disord       Date:  2021-06-25       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.