Literature DB >> 27475919

Customized procedure to display T-Scan occlusal contacts.

Eneko Solaberrieta1, Olatz Etxaniz2, Jose Ramon Otegi3, Aritza Brizuela4, Guillermo Pradies5.   

Abstract

The virtual technique described in this article integrates reverse engineering and mandibular dynamics into dental computer-aided design and computer-aided manufacturing (CAD-CAM) systems. This technique aims to provide more objective information to the dental technician for the diagnosis, planning, and treatment phases. In order to carry out this protocol, the following devices, currently available in many practices, are necessary: an intraoral scanner, a T-Scan system, and some specific open reverse engineering software. By means of a virtual procedure, the T-Scan system detects the occlusal contacts, and the occlusal surfaces are obtained using an intraoral scanner. Once the alignment between the 3-dimensional occlusal surface and the T-Scan registration is carried out, the resulting contacts are projected onto the patient's occlusal surfaces; in this way, occlusal forces are obtained over time. The results obtained with this procedure demonstrate the feasibility of integrating different tools and software and the full integration of this procedure into a dental digital workflow.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27475919     DOI: 10.1016/j.prosdent.2016.07.006

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Comparison of two different digital occlusal analysis methods.

Authors:  Sibel Ezgi Bostancıoğlu; Abdullah Toğay; Evşen Tamam
Journal:  Clin Oral Investig       Date:  2021-10-01       Impact factor: 3.573

2.  Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices.

Authors:  Cristina Fraile; Alberto Ferreiroa; Marta Romeo; Raquel Alonso; Guillermo Pradíes
Journal:  Clin Oral Investig       Date:  2021-09-14       Impact factor: 3.606

3.  Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices.

Authors:  Cristina Fraile; Alberto Ferreiroa; Marta Romeo Rubio; Raquel Alonso; Guillermo Pradíes Ramiro
Journal:  Clin Oral Investig       Date:  2022-05-18       Impact factor: 3.606

4.  Evaluation of the Accuracy of a System to Align Occlusal Dynamic Data on 3D Digital Casts.

Authors:  Iñigo de Prado; Mikel Iturrate; Rikardo Minguez; Eneko Solaberrieta
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.